SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 79 729 VS: Upload data incorrect CAUSE ● Obsolete MV S software, MVS error. REMEDY ● Reboot; up dat…

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 78
722 VS: Error during memory request
CAUSE
●
Software error
REMEDY
●
Reboot; inform Development.
723 VS: File could not be opened
CAUSE
●
File does not exist in the station computer (TISCH.HEX)
REMEDY
●
Reinstall software (possibly only TISCH.HEX)
724 VS: Error during memory request
CAUSE
●
Not enough memory available in the station computer
REMEDY
●
Reset station computer
725 VS: Error during memory release in VS load
CAUSE
●
Software error
REMEDY
●
Inform Development.
726 VS: Error in message reception
CAUSE
●
Software error
REMEDY
●
Inform Development; possibly reboot.
727 VS: Error in send function in SC
CAUSE
●
Software error
REMEDY
●
Inform Development; possibly reboot.
728 VS: Unknown state
CAUSE
●
Software error
REMEDY
●
Inform Development; possibly reboot.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 79
729 VS: Upload data incorrect
CAUSE
●
Obsolete MVS software, MVS error.
REMEDY
●
Reboot; update eproms (MVS).
730 NF: software error
CAUSE
●
Incorrect message at NF (Info1)
REMEDY
●
If possible, ignore; possibly reboot.
731 NF: GLC NOK
CAUSE
●
Internal transmission error
REMEDY
●
Try again; if possible, ignore.
732 MA data: unknown spacer type
CAUSE
●
In aktuell.ma or *.vkl there is a spacer type which cannot be found in real.ma.
REMEDY
●
Establish consistency in the files aktuell.ma, *vkl and real.ma.
733 SF: unexpected input:
CAUSE
●
Incorrect message to single function (Info1), operator error during transition to single function or fatal
error handling ( start button not pressed )
REMEDY
●
If possible, ignore; possibly reboot.
734 SF: answer from wrong MC
CAUSE
●
System error
REMEDY
●
Reboot
735 SF: global communication not ok
CAUSE
●
Communication between machine controller and station computer disturbed.
REMEDY
●
Try communicating again.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 80
736 GK: Error in local machine data
CAUSE
●
There are no real or current machine data on the hard disk; the machine data cannot be converted
due to a structure error.
REMEDY
●
Write the MA data onto the hard disk properly.
737 GK: Error in machine data
CAUSE
●
The MA data (ideal) coming from the line computer cannot be converted.
REMEDY
●
The correct data format must be sent.
738 GK: Error in set-up data
CAUSE
●
The set-up data coming from the line computer cannot be converted.
REMEDY
●
The correct data format must be sent.
739 GK: Error in cluster data
CAUSE
●
The cluster data coming from the line computer cannot be converted.
REMEDY
●
The correct data format must be sent.
740 GK: Error in fiducial data
CAUSE
●
The fiducial data coming from the line computer cannot be converted.
REMEDY
●
The correct data format must be sent.
741 GK: Error in package form data
CAUSE
●
The package form data coming from the line computer cannot be converted.
REMEDY
●
The correct data format must be sent.
742 LRS: Timeout during transmission to line computer
CAUSE
●
Released through IEC bus
REMEDY
●
Reboot