418 FM_FEHLER_6
CAUSE
Error during testing, significance varies.
REMEDY
419 FM_FEHLER_7
CAUSE
Error during testing, significance varies.
REMEDY
420 FM_FEHLER_8
CAUSE
Error during testing, significance varies.
REMEDY
421 FM_FEHLER_9
CAUSE
Error during testing, significance varies.
REMEDY
422 FM_FEHLER_10
CAUSE
Error during testing, significance varies.
REMEDY
423 Position: Evaluation not possible
CAUSE
Component is not positioned properly at the nozzle, or is missing; optical image inadequate.
REMEDY
Change the illumination values and / or the LUT.
424 Dimension: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
Optimize pick-up; check charge (component).
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 51
425 No. of pins: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
Optimize pick-up; check charge (component).
426 Colinearity: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
Optimize pick-up; check charge (component).
427 Spacing: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
Optimize pick-up; check charge (component).
428 Position: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
429 Dimension: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
430 No. of pins: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 52
431 Colinearity: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
432 Spacing: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
433 Position: Component outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
434 Dimension: Comp. outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
435 No. of pins: Comp. outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
436 Colinearity: Cmp. outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
437 Spacing: Component outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.