SG_FSE_SiplaceHF_HF3_00193901-05_eng.pdf - 第119页

1 - 5 S tudent Guide SIPLACE HF/HF3 Edition 09/2005 4 Servic es to the machine 5 K5 contactor A1(+)– A2 (-) 1,2 3,4 5,6 24VDC 24 VDC to GND 24 VDC to GND 24 VDC to GND K6 (SSK) safety combination L+, X3, X5 24 VDC t o GN…

100%1 / 596
1 - 4
Student Guide SIPLACE HF/HF3
4 Services to the machine Edition 09/2005
4
4.1.1 Overview power supply
Fig. 4.1 - 2 main power supply unit identical in original - and ’A’ version of the HF-Machine
Legend
(1) DC/DC Converter 24 V (4) Fuse F5 for star axis
(2) DC/DC Converter 5 V at HFand 5V/24V at HF3 (5) Fuse F11 for inrush current limiter
(3) Safety combination relay K6
1
2
3
4
5
main distributor main
power supply
Inrush current limiter:
a: transformer: EST
b: servo: Ess
transformer T2
transformer T1
T1
T2
Fuse F61 - fuse F142
Units Identification Contact Voltages
X100 main power supply L1, L2, L3 3 x 204 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
X102 service socket 115 VAC / 220 VAC / 230 VAC / 240 VAC
Q1 main switch 1, 3, 5 u.
2, 4, 6
3 x 204 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
Q2 motor circuit breaker 1, 3, 5 u.
2, 4, 6
3 x 204 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
K1 main contactor 1, 3, 5 u.
2, 4, 6
3 x 204 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
K2 contactor 1, 3, 5 u.
2, 4, 6
3 x 177 VAC
K3 contactor 1, 3, 5 u.
2, 4, 6
3 x 177 VAC
K4 contactor 1, 3, 5 u.
2, 4, 6
3 x 177 VAC
1 - 5
Student Guide SIPLACE HF/HF3
Edition 09/2005 4 Services to the machine
5
K5 contactor A1(+)– A2 (-)
1,2
3,4
5,6
24VDC
24 VDC to GND
24 VDC to GND
24 VDC to GND
K6 (SSK) safety combination L+, X3, X5 24 VDC to GND
F1 fuse service socket;
1-pol.
1, 2 115 VAC / 220 VAC
230 VAC / 240 VAC
F2 fuse co-table;
3-pol.
1, 3, 5 u.
2, 4, 6
3 x 36 VAC
F4 fuse X- / Y-axis;
3-phase.
1, 3, 5 u.
2, 4, 6
3 x 177 VAC
F5 fuse star-axis;
1-phase
1, 2 145 VDC to GND
F6 fuse Z- and DP-axis;
1-phase.
1, 2 39 VDC to GND
F7 fuse secundary circuit;
3-phase
1, 3, 5 u.
2, 4, 6
3 x 230 VAC
F8 fuse PCB-transport;
1-phase
1, 2 33 VDC to GND
F10 fuse rectifier V7 and V70;
3-phase
1, 3, 5 u.
2, 4, 6
3 x 39 VAC
F11 fuse inrush current limiter
1-phase
1, 2 33,6 VDC to GND
F12 fuse illumination
1-pol.
1, 2 52 VDC to GND
F13 fuse monitor;
1-pol.
1, 2 26 VDC to GND
F14 fuse Y-motor cooling device
1-phase
1, 2 26 VDC to GND
F61 / F62 fuse rectifier V4 3 x 28 VAC
F81 / F82 fuse rectifier V5 3 x 23,8 VAC
F111 / F112 fuse rectifier V8 3 x 23,8 VAC
F131 / F132 fuse rectifier V10 3 x 19,7 VAC
F141 / F142 fuse rectifier V11 3 x 18,7 VAC
1 - 6
Student Guide SIPLACE HF/HF3
4 Services to the machine Edition 09/2005
6
Notes