SG_FSE_SiplaceHF_HF3_00193901-05_eng.pdf - 第437页

1 - 9 S tudent Guide SIPLACE HF/HF3 Edition 09/2005 10 Sitest 9 10.2 Calibration WA R N I N G During some of the procedure s the gantries will traverse. Therefore, before you beg in with any of these pr ocedure s make su…

100%1 / 596
1 - 8
Student Guide SIPLACE HF/HF3
10 Sitest Edition 09/2005
8
7.
8.
MTC
Calls the view for the functions
of the MTC.
Calls the view for the tower
functions of the MTC.
Calls the view for the axis
functions of the MTC.
Calls the view for the settings of
the MTC.
Calls the view for the machine
data functions of the MTC.
Calls the view for the inputs/
outputs of the MTC.
Calls the view for the inputs/
outputs of the MTC.
Inputs/Outputs
I/O module 1
I/O module 2
I/O module 3
I/O module 4
I/O module 5
I/O module 6
Lifting table and stopper, conveyor 1
Lifting table and stopper, conveyor 2
Belt motor, sonar Bero and width
adjustment, conveyor 1
Belt motor, sonar Bero and width
adjustment, conveyor 2
Interface, conveyor 1
Interface, conveyor 2
Options, conveyor 1
Options, conveyor 2
Conveyor width adjustment
1 - 9
Student Guide SIPLACE HF/HF3
Edition 09/2005 10 Sitest
9
10.2 Calibration
WARNING
During some of the procedures the gantries will traverse.
Therefore, before you begin with any of these procedures make sure that you and everyone else
stay physically clear of the travel range of the gantries.
RISK OF INJURY!
Also, ascertain, that no objects are in the way. 10
10
Note:
Before you begin with the calibration, you must reference the heads and the gantries.
During calibration, unused gantries will automatically be traversed to their parking position.
For a complete calibration of the placement system, the SITEST test program provides the func-
tion
"Calibrate machine..." which allows you to start all calibration functions from the menu "Calibrate
entire machine".
Calibration functions will be performed for these functions, for gantries 1, and 2. 10
Equipment and Testing Tools
Test program SITEST, version 504.xx
Calibration tools
Nozzles, type 956, 517,518
Gauge
PCB, width 100 mm
1 - 10
Student Guide SIPLACE HF/HF3
10 Sitest Edition 09/2005
10
10.2.1 Calibration in general
Fig. 10.2 - 1 General sequence to calibrate the machine
Note:
Since the head modularity concept means that either a Twin Head or a C&P head can be fitted to
each gantry, the functions displayed for processing area 1(PA1) and processing area 2 (PA2) re-
spectively may vary. The functions described for PA1 and PA2 below apply for a Twin Head con-
figured on gantry 2 and a C&P head configured on gantry 1.
Sequence of calibrate the HF/HF3 machine with SW 505
Preperation the machine
All heads and cameras..
Sitest: Button "Calibrate machine...."
Calibrate and teach
of positions
PCB Mapping
Head Mapping
Gantry 1
(HF,HF3)
Gantry 3
(HF,HF3)
Calibrate and teach
of positions..
PCB Mapping
Head Mapping
Gantry 4
(HF3)
Calibrate and teach
of positions..
PCB Mapping
Head Mapping