SG_FSE_SiplaceHF_HF3_00193901-05_eng.pdf - 第208页
1 - 8 S tudent Guide SIPLACE HF/HF3 6 Collect &Place-He ad / DLM2 Edition 09/2005 8 6 Fig. 6.1 - 5 DLM2 6 segment Collect&Place head - parts overview 3 6 Item in Fig. Designation 1 Star fitted / DLM2 2 "Z-ax…

1 - 7
Student Guide SIPLACE HF/HF3
Edition 09/2005 6 Collect &Place-Head / DLM2
7
6
Fig. 6.1 - 4 DLM2 Collect&Place head - parts overview 2
Item Designation Item no.
1 Air kiss unit / DLM2 00367793-01
2 Silencer 03003134-01
3 Turning station / DLM2 00341780-03
424
x24 component camera KST 00336791-03

1 - 8
Student Guide SIPLACE HF/HF3
6 Collect &Place-Head / DLM2 Edition 09/2005
8
6
Fig. 6.1 - 5 DLM2 6 segment Collect&Place head - parts overview 3
6
Item in Fig. Designation
1 Star fitted / DLM2
2 "Z-axis down" sensor
3 RSF digital encoder 12/DLM2

1 - 9
Student Guide SIPLACE HF/HF3
Edition 09/2005 6 Collect &Place-Head / DLM2
9
6.1.5 Pressure air supply DLM 2 C&P head
Fig. 6.1 - 6 Pressure air connectors C&P head
6.1.5.1 Vacuum generator DLM 2
Fig. 6.1 - 7 Vacuum generator DLM 2 head
(1) Pressure air connector for C&P-head Va-
cuum-holding circuit 4,7 bar Input pressure air
for the Placement head
(2) Pressure air connector for C&P-head Va-
cuum-pick up circuit with branching for the air
kiss supply 4,7 bar Input pressure air for the
Placement head
(3)-(5) Blind connector (Connector for Twin head)
Pressure air connector for cooling
X-Motor
(1) Holding circuit
(2) Pick up- and Placement circuit
w
ith branching for air kiss
V
acuum measuring board
Pressure air connector for cooling
the X-motor on the silencer (exhaust
air from the vacuum system)