SG_FSE_SiplaceHF_HF3_00193901-05_eng.pdf - 第356页

1 - 8 S tudent Guide SIPLACE HF/HF3 7 TWIN-Head Edition 09/2005 8 7 Fig. 7.6 - 3 Digital track signals TWIN- head axes at axis test box Please Note: The Zero pulse at axis tester is inverted to th e digit al zero pulse f…

100%1 / 596
1 - 7
Student Guide SIPLACE HF/HF3
Edition 09/2005 7 TWIN-Head
7
7.6.2 Track signals head axes
The track signals undertake the main control function in the case of the new drive concept of the
HF machine. They are responsible for the exact and precise positioning of the axes and are used
as only response of the closed-loop control system so that the track signals have an important
influence on dynamics of the axes.
7.6.2.1 Test set up
Fig. 7.6 - 2 General test set up to check the analoge track signals TWIN- Z-axis
The analoge track signals of the TWIN- head Z-axes are measurable on the incremental encoder.
Please Note:
The digital track signals of the TWIN- head can only be measured on the axis test box.
The track signals of theTWIN head D-axes can only be measured as digital signals on the axis
test box. 7
1 - 8
Student Guide SIPLACE HF/HF3
7 TWIN-Head Edition 09/2005
8
7
Fig. 7.6 - 3 Digital track signals TWIN- head axes at axis test box
Please Note:
The Zero pulse at axis tester is inverted to the digital zero pulse from the ’Schmitt Trigger’. 7
1 - 9
Student Guide SIPLACE HF/HF3
Edition 09/2005 7 TWIN-Head
9
7.6.3 Axis control TWIN- Head Z-axis
The Z axis is driven with a 3 phase AC linear motor with an intermediate circuit voltage of 60V.
The control of the axis occurred with two control signals of the VC3 (dephasing 120°) controller
I
nom "W" and I nom "U". The third phase is calculated at Servo amplifier.
Fig. 7.6 - 4 Axis control Z-axis TWIN- head
7.6.3.1 Check the dynamic of Z-axis
Please Note:
For check the dynamic please use the official Adjustment manual.
Axis board A363 with VC 3 Controller (VC = Velocity Commutation)
Control signals I
soll "W" and I soll "U"
Servo board control directly the linear motor, Intermediate (DC) voltage cir-
cuit is 250V.
LED‘s on Servo board:
Power supply ON
Servo enable, it the enable signal from the axis board.
–Display I
RMS limit shorter than 2,5 s.
Error: Over voltage, -current, -temperature longer than 2,5 sec.
3 Phase AC linear motor with integreted temperatur sensor.
Between motor and incremental scale exist a fixed mechanically connec-
tion.The incremental encoder is fixed on the frame of the TWIN- head.
Incremental encoder: Transmitted the correct position to the axis board and
is the only feedback signal to control the motor (Track signals).
Force sensor