1 - 44 S tudent Guide SIPLACE HF/HF3 1 1 MTC 2 Edition 09/2005 44 Fig. 1 1.3 - 10 Overview "Calib ration feed axes 1/2" Calls the view for the functions of the MTC. Calls the view for the tower functions of the…

100%1 / 596
1 - 43
Student Guide SIPLACE HF/HF3
Edition 09/2005 11 MTC 2
43
2b. Transfer position of the Tower 2 WTC 11
When you press the button to calibrate the Transfer position the tray moves out and stops approx.
5mm before the feed axis end.
Attention:
When you accept this calibration procedure with "ACCEPT" now, you get a wrong transfer position
and pick up position for the twin head.
Then move the tray in the direction to the machine and stop so that the plastic edge comes into
line with outer edge of the frame from the feed axis. You must do this in one step, because that
you eliminate the tolerance between the space and the driver and you don‘t need a pick up
offset for the tray.
Fig. 11.3 - 9 Transfer position JEDEC tray
During the production the trays move a different way to her pick up position but the Y Position of
the machinen (pick up postion) of both trays is the same.
Plastic edge of the WTC
Edge of the frame from the MTC
1 - 44
Student Guide SIPLACE HF/HF3
11 MTC 2 Edition 09/2005
44
Fig. 11.3 - 10 Overview "Calibration feed axes 1/2"
Calls the view for the functions
of the MTC.
Calls the view for the tower
functions of the MTC.
Calls the view for the axis
functions of the MTC.
Calls the view for the settings of
the MTC.
Calls the view for the machine
data functions of the MTC.
Calls the view for the inputs/
outputs of the MTC.
Calls the view for the inputs/
outputs of the MTC.
Return to the main view.
Selects the MTC
at location 2 or 4.
Axis
Feed axis
The selected functions are
executed for the feed axis.
Lifting axis
The selected functions are
executed for the lifting axis.
Tower
1/2
Activates the functions
for tower 1 or tower 2.
Info
Current position:
Shows the current position of the activated axis in µm.
Update position
Updates the display for the position of the activated axis.
Travel range
Limit switch +
Moves the selected axis to the limit
switch in order to re-determine the
maximum position which can be
reached. A reference run is then
performed with the axis.
Limit switch -
Moves the selected axis to the limit
switch in order to re-determine the
minimum position which can be
reached. A reference run is then
performed with the axis.
The feed axis is deactivated when the protective cover is opened.
The end of the slide rail of the feed axis is physically adjusted so
that it comes into line with the outer edge of the waffle pack tray
carrier in Level 1. This position can then be accepted as the new
transfer position by clicking OK.
1 - 45
Student Guide SIPLACE HF/HF3
Edition 09/2005 11 MTC 2
45
Fig. 11.3 - 11 Overview "Calibration feed axes 2/2"
Catch
Engage
The catch is engaged in the waffle pack
tray carrier. This allows a waffle pack tray
carrier to be moved out of the tower.
Disengage
The catch is then disengaged, so that the
tower can be moved.
Apply
Applies the taught position. A reference
run is then started.
Opens the Teach removal
position dialog box where you can
select the cassette for which the
removal position is to be taught.
Select the cassette
for which the removal
position is to be
determined.
After selecting the cassette the saved
removal position is approached and
the Teach removal position dialog
box is opened which allows you
engage or disengage the catch.