SG_FSE_SiplaceHF_HF3_00193901-05_eng.pdf - 第538页

1 - 64 S tudent Guide SIPLACE HF/HF3 1 1 MTC 2 Edition 09/2005 64 1 1.3.4.5 Disengaging mechanism T ools and accessories 11 – 1 set of hexagon socket wrenches Prep aratory measures 11 ➠ Empty the MTC 2 completely (see th…

100%1 / 596
1 - 63
Student Guide SIPLACE HF/HF3
Edition 09/2005 11 MTC 2
63
On the adjustment gauge the light barrier should still shine through at a height of 9,75 mm and
at a height of 9,85 mm the light should be interrupted.
Place the adjustment gauge for the crash light barriers along of a empty WPC onto the rail of
the feed axis for tower 2.
Unscrew the clamping screws of the holder for tower 2 and the middle holder (movable section)
and place the bottom light barrier pair onto the middle of the gauge. Ensure that the holders do
not jam in their guide.
Firmly tighten the clamping screws. Ensure that the holders cannot be moved or turned any
more.
At this setting, the bottom light barrier pair should still just shine through at a height of
11.40 mm + 0.05 mm and no longer shine through at a height of 11.50 mm + 0.05 mm.
Fig. 11.3 - 25 Checking and setting the crash light barriers
Key
1 Crash light barriers for tower 1
2 Crash light barriers for tower 2
3 Light barrier holder for tower 1 with clamping screws
4 Middle light barrier holder with clamping screws, base section
5 Middle light barrier holder with clamping screws, movable section
6 Light barrier holder for tower 2 with clamping screws
4
2
1
3
5
6
1 - 64
Student Guide SIPLACE HF/HF3
11 MTC 2 Edition 09/2005
64
11.3.4.5 Disengaging mechanism
Tools and accessories 11
1 set of hexagon socket wrenches
Preparatory measures 11
Empty the MTC 2 completely (see the User Manual).
Move the feed axis into the zero position (see section11.3.2.2 ) and engage the driver in the
WTC.
Setting the disengaging mechanism 11
Move the driver over the belt until it lies outside the disengaging mechanism.
Check that the driver in its dead center position engages centrally with the disengaging
aperture when it is moved back.
When the guide roller is pushed through the middle of the aperture, set the position of the
aperture with the 4 securing screws of the disengaging mechanism.
Fig. 11.3 - 26 Setting the disengaging mechanism
Key
1 Driver guide roller in dead center position
2 Disengaging mechanism aperture
3 Disengaging mechanism securing screws
2
3
1
1 - 65
Student Guide SIPLACE HF/HF3
Edition 09/2005 11 MTC 2
65
11.3.5 Converting the power supply
To operate the MTC 2 in the USA or in Japan, the power supply needs to be changed from 400
V, 50 Hz to 208/204 V, 50/60 Hz.
NOTE
To convert the power supply from 208/204 V to 400 V, the same procedure must be carried out in
the reverse order.
Tools and accessories 11
1 set of screwdrivers
3 additional bridges
11.3.5.1 Procedure
Fig. 11.3 - 27 Electronics board
Key
1 Bridges on the voltage distributor terminal X01
2 Motor protection switch
2
1