SG_FSE_SiplaceHF_HF3_00193901-05_eng.pdf - 第162页
1 - 48 S tudent Guide SIPLACE HF/HF3 4 Services to the machine Edition 09/2005 48 4.3.8.1 Air distribution TWIN-head 4 Fig. 4.3 - 18 air distribution TWIN-head 4 Legend : 1. sealed 2. air supply TWIN-head segment 1 vacuu…

1 - 47
Student Guide SIPLACE HF/HF3
Edition 09/2005 4 Services to the machine
47
4.3.8 Pneumatic Supply Twin Head:
The 4.8 bar air supply is also used for following basic application on the Twin head:
– vacuum
– air kiss
– retract spring for z-axis
– cooling X-axis motor
4
Fig. 4.3 - 17 pneumatic distribution Twin head
Legend:
1. retracting cylinder for Z-axisTWIN-head segment
2. vacuum generator TWIN-head segment1
3. retracting cylinder for Z-axis twin head segment 2
4. vacuum generator TWIN-head segment 2
5. cylinder with spring for retracting Z-axis in fail mode
6. valve for Z-axis retract process in fail mode (controlled by power fail)
3 4
1 2
4.6 +0.1 bar

1 - 48
Student Guide SIPLACE HF/HF3
4 Services to the machine Edition 09/2005
48
4.3.8.1 Air distribution TWIN-head
4
Fig. 4.3 - 18 air distribution TWIN-head
4
Legend
:
1. sealed
2. air supply TWIN-head segment 1 vacuum-air kiss generator
3. air supply TWIN-head segment 1 Z-axis power fail safety unit
4. air supply TWIN-head segment 2 vacuum-air kiss generator
5. air supply TWIN-head segment 2 Z-axis power fail safety unit
4
4
4
4
4
4
4
4
4
4
1 2 3 4 5

1 - 49
Student Guide SIPLACE HF/HF3
Edition 09/2005 4 Services to the machine
49
vacuum and air kiss at Twin head 4
The vacuum generation and the vacuum regulation at the Twin head is a fully sophisticated
new process. The vacuum and air kiss is not anymore seperated, as known from former vac-
uum systems we used. Furthermore, 1 venturi system is used for vacuum and air kiss by con-
trolling it through an adjustable piston. Depending on the position of this piston 3 different
states are to regulate.
4
state 1: normal vacuum generation (max. vacuum) 4
state 2: regulated and controlled vacuum 4
state 3: no vacuum, air kiss in case 4
Fig. 4.3 - 19 TWIN-head max. vacuum
Fig. 4.3 - 20 regulated vacuum
Fig. 4.3 - 21 air kiss
Input compressed
air 4.6 bar
1
2
3
4
air exhaust (open)
max. vacuum
Legend:
1. venturi nozzle
2. plunger for vacuum / airkiss
generation
3. vacuum / airkiss
4. exhaust pipe
Input compressed
air 4.6 bar
1
2
3
4
air exhaust (open)
medium vacuum
Input compressed
air 4.6 bar
1
2
3
4
air kiss air exhaust (blocked)air kiss