SG_FSE_SiplaceHF_HF3_00193901-05_eng.pdf - 第134页
1 - 20 S tudent Guide SIPLACE HF/HF3 4 Services to the machine Edition 09/2005 20 4.2.7 DC/DC Converte r Vision section 2 This DC/DC converter is only used for generating 42 V for P&P came ra illumination as well as …

1 - 19
Student Guide SIPLACE HF/HF3
Edition 09/2005 4 Services to the machine
19
4.2.6 Power Supply Axis Unit
When the main switch is on, the axis unit is supplied with 52 V from main power supply via X13
and generates the voltages as shown below.
The +-15V and 5V supply voltages for the servo unit’s electronic circuits are generated from the
two DC/DC converter, which are integrated in the servo unit. This DC/DC converter generates the
5V and +- 15V needed for the servo board and the axis controller and the +-15V are also used on
placement heads and anti-crash, for e.g. It will travel to main distributor X4qa (sector 2) and then
to terminal block X1qa and get distributed from here.
4
4
4
Fig. 4.2 - 10 DC/DC converter axis unit
1
2
o
o
power supply on top: +-15 / 5V
o
o
o
1
+5V Axis controller
+15V Servo
-15V Servo
GND
2
-15V axis controller and machine
+15V axis controller and machine
power supply bottom: +-15 V
GND
GND
power supply
52 VDC
5 VDC
U6
T1
U7
F10
main power supply distributor
52 VDC
+5 VDC
+- 15 VDC
52 VDC
+-15 VDC
2
1
axis unit

1 - 20
Student Guide SIPLACE HF/HF3
4 Services to the machine Edition 09/2005
20
4.2.7 DC/DC Converter Vision section 2
This DC/DC converter is only used for generating 42 V for P&P camera illumination as well as the
power distribution for PCB camera (5/24V) and component camera (24V).
Fig. 4.2 - 11 DC/DC converter section 2
4.2.7.1 Power Supply Tape Cutter
The tape cutter are arranged in a parallel and a serial mode. The tape cutter in sector 2 and sector
3 are serial, tape cutter in sector 1 and sector 4 are also arranged in serial mode
Fig. 4.2 - 12 power supply tape cutter
52 VDC
42 VDC
m
a
i
n
p
o
w
e
r
s
u
p
p
l
y
d
i
s
t
r
i
b
u
t
o
r
5/24 V for PCB &
Co-camera
52V
5/24V
42 V
vision
control
unit
stationary
camera 1
stationary
camera 2
(optional)
main distributor, section 2
placement area 2
X4qd
X5qd
X2qa
X71qa X22qa
tape cutter 3
X17qa
tape cutter 2
SSK
X16
X71ra X22ra
tape cutter 4
X17ra
tape cutter 1
X21ra
2
4
V
power supply
tape cutter
main valve
X60

1 - 21
Student Guide SIPLACE HF/HF3
Edition 09/2005 4 Services to the machine
21
4.2.8 Safety and Control Loop(HF/HF3 bis MA.Nr. xx)
Please Note: For machine type A you consult the enclosed circuit diagrams.
4.2.8.1 Émergency Stop Loop (safety loop)
Following contacts are switched in serial and build the safety loop: _ 4
– 4 protective cover switches (main cover).
– conveyor cover switch.
– contact on component change over table
– emergency stop button must be released
Fig. 4.2 - 13 safety loop
If the emergency stop loop is closed, 24 V will be present on K5, contact 3. Another 24 V signal
travels to each CAN I/O module as
’emergency stop loop OK’ and signalize that all covers are
closed and table connected.
security loop START
sub distributor section 4
main distributor section 2
24 V
X1ra
input
conv.
left
X11ra
X11ra
input
conv.
right
X12ra
X12ra
cover 1
X13ra
X13ra
cover 4
X14ra
X14ra
table 1
X18ra
X18ra
table 4
X23ra
X23ra
X72qa
output
conv.
right
X11qa
X11qa
output
conv.
left
X12qa
X12qa
cover 2
X13qa
X13qa
cover 3
X14qa
X14qa
table 2
X18qa
X18qa
table 3
X23qa
X23qa
X16
K5
CAN I/O
CAN I/O
X2qa
X73qa
section 2
section 4
24 V
power supply
SSK
24 V
24 V
24 V
electrical isolation
(optical coupler)
GND
input
input
X16
&
d
i
s
t
i
b
u
t
o
r
d
i
s
t
i
b
u
t
o
r