SG_FSE_SiplaceHF_HF3_00193901-05_eng.pdf - 第299页
1 - 99 S tudent Guide SIPLACE HF/HF3 Edition 09/2005 6 Colle ct &Place-Head / DLM2 99 6.7.4 Head exchange 1. Mak e an bac k u p f or t he exi s t ma c hi neconf i gur ati on. 2. Ma c hi ne da ta - backup wit h t he S…

1 - 98
Student Guide SIPLACE HF/HF3
6 Collect &Place-Head / DLM2 Edition 09/2005
98
Fig. 6.7 - 4 Means of deciding between 12 segment C&P head or 6 segment C&P head w/o DCA camera
Please Note:
For the Option Head Modularity please use the retrofitting instruction "Head Reconfiguration kits
Item no. 00193893-02.
Component size > 18,7x18,7mm
Component height > 6mm
?
BE weight > 2g?
0201 or BARE DIE
Flip chip placement?
6 segment C&P head
C&P head with DCA Camera
6 segment C&P head
Yes
Yes
Yes
12 Segment C&P head
No
No
No
12 Segment C&P head with
standard camera
Deciding factors about the choice of the C & P heads and the camera types.

1 - 99
Student Guide SIPLACE HF/HF3
Edition 09/2005 6 Collect &Place-Head / DLM2
99
6.7.4 Head exchange
1. Make an backup for the exist
machineconfiguration.
2. Machine data - backup with the
Sitest and create a folder
e.g. Backup and store the folder
SRCMA.
3. Store the Ideal.ma file
4. Sitest " Head exchange" store all
zero point correction into the head-
EPROM.
5. Mechanical works:
Head exchange, Nozzlechanger
exchange.
6. Switch ON the machine and
configure in the SITEST the new
machineconfiguration (head type
and type of the nozzlechanger).
Note: After the reconfiguration
shutdown the machine switch off and
on again.
7. Siplace Pro computer:
Make a copy of the exist basic set
up and configure into the copy the
new head type and nozzlechanger
Note: As a result the new Ideal.ma file
will be send to the station.
8. Siplace Pro computer:
Send a placement program, e.g.
with one component to the station.
9. Station:
Determine the zero point correction
of the star axis, check the axis
dynamic and calibrate all heads
and cameras.
10. Station:
With increase placement accuracy
carring out the fine calibration.

1 - 100
Student Guide SIPLACE HF/HF3
6 Collect &Place-Head / DLM2 Edition 09/2005
100
6.7.5 Menu Head exchange
Fig. 6.7 - 5 Menu "Head exchange" --> "Head data"
Fig. 6.7 - 6 Menu "Head exchange" --> "Axis data
(1) Read data from “head memory” write to RAM.
(2) Read data from RAM (MA data file) and write to “head memory”.
(3) Data taken from selected axis at RAM
(4) Data taken from selected axis at RAM (open to edit).
(5) Select head axis
(6) Link to this menu in placement head, axis reference run and head reference run.
1
6
5
4
3
2