SG_FSE_SiplaceHF_HF3_00193901-05_eng.pdf - 第35页

1 - 9 S tudent Guide SIPLACE HF/HF3 Edition 09/2005 2 Overview 9 Fig. 2.2 - 2 Siplace HF3 Legend (1) Sec tor 1 (2) Se ctor 2 (Main Distr ibutor) (3) Sec tor 3 (4) Secto r 4 (Sub Distributer ) (5) T ransport directio n (6…

100%1 / 596
1 - 8
Student Guide SIPLACE HF/HF3
2 Overview Edition 09/2005
8
2.2 Overview Units
2.2.1 Switches
Fig. 2.2 - 1 Siplace HF3
(1) Main switch
(2)
Stop button (Black) on the side of Main Power Supply, and pneumatic supply and input side (the first
version had on both sides of the conveyor this button)
(3)
Start button (White) on the side of Main Power Supply, pneumatic supply and input side (the first version
had on both sides of the conveyor this button)
(4) Component Counter on the operater side (Side on the Main Power Supply)
(5) Emergency stop button on the input conveyor side and output conveyor side
(6)
Start button (white) on the output conveyor side (the first version had on both sides of the conveyor
this button)
(7)
Stop button (black) on the output conveyor side (the first version had on both sides of the conveyor
this button)
(8) Service socket inside the power supply unit behind the safety cover
(9) Schmersal safety swtches input- output covers (only at original machine version)
T Transport direction
1
7
9
8
3
5
6
4
T
2
1 - 9
Student Guide SIPLACE HF/HF3
Edition 09/2005 2 Overview
9
Fig. 2.2 - 2 Siplace HF3
Legend
(1) Sector 1 (2) Sector 2 (Main Distributor)
(3) Sector 3 (4) Sector 4 (Sub Distributer)
(5) Transport direction (6) Pneumatic unit & Control unit conveyor
(7) Component changeover table (8) Computer unit
(9) Position for Component changeover table
or MTC 2 for BB 2
(10) Position for Component changeover table
or MTC 2 for BB 1 (MTC only HF)
(11) Axis unit in PA 1 for HF3 (12) Axis unit in PA 2
(13) Power supply unit
1
2
8
3
5
6
4
7
7
9
10
11
PA 1
PA 2
13
12
1 - 10
Student Guide SIPLACE HF/HF3
2 Overview Edition 09/2005
10
2.2.2 Power supply unit
The main power supply unit is mounted on a compact slide-in module, and located on the left side
of the middle section. When viewed from the outside only the red main power switch is visible.
A lockable door prevents access to the unit.
Fig. 2.2 - 3 Power supply
Legend
(1) DC / DC Converter 24 V (2) DC / DC Converter 5 V and 5V/24V for HF3
(3) Safety combination relais K6 (4) F5 fuse for Star axis
(5) F11for Inrush current limiter transformer
1
2
3
4
5
main distributor main
power supply
Inrush current limiter:
a: transformer: EST
b: servo: Ess
transformer T2
transformer T1
T1
T2
Fuse F61 - fuse F142