Communication and Control Reading the Board IDs out of the EEPROM Board IDs Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 140 Reading the Board IDs ou t of the EEPROM 4.6.2 Reading the Board IDs out of the EEPROM The…

100%1 / 522
Communication and Control
Board IDs What are Board IDs?
139 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
SIPLACE X series:
Head interface (gantry 1 - 4)
Head adapter (C&P20, C&P6/12, Twin head)
Intermediate Distributor - C&P20
Main board Twin Head
Vision board (gantry 1 - 4)
Illumination board stationary Cameras (Location 2/4)
Vacuum sensor holding circuit board C&P20
Overview of board IDs, checked by the TQM module (SIPLACE X series and X4I with SW 70x)
In X series machines with TQM, the PCB ID is read out of the BIOS.
In X series machines with HCU, the PCB ID is read out of the application.
Board IDs for Vision boards (SIPLACE X)
NOTICE
The same PCB IDs apply for the SIPLACE X4I, even if head modularity is not possible.
NOTICE
The board ID for the Vision board (gantries 1 - 4), the illumination board for the stationary
cameras (sector 2/4) and the holding circuit vacuum sensor board for C&P20 are currently not
evaluated.
Communication and Control
Reading the Board IDs out of the EEPROM Board IDs
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 140
Reading the Board IDs ou t of the EEPROM
4.6.2 Reading the Board IDs out of the EEPROM
The board ID can be checked with the help of the Cacciatool.
You can use CAN Bus commands to read the board type IDs or open the corresponding menu to read
the memory of the EEPROM. When one or more ID‘s are missing so you can write the correct ID on the
board.
At the moment it is necessary to use the correct ID‘s on the board which are installed on the gantry (Head
interface, - adapter, Intermediate distributor and main board). The other board type ID‘s are not used at
the moment.
Reading Out the Board Type ID via the Grippe r Menu
4.6.2.1 Reading Out the Board Type ID via the Gripper Menu
Switch off the machine.
Connect the service laptop to the machine CAN bus at PA1 and/or PA2.
Make sure that the cable is connected at channel 1 for PA1 and at channel 2 for PA2 of the Kvaser
card.
Switch on the machine
Start the Caccia software and check the machine configuration in Caccia.
Doubleclick on the Open Subsystem Control Center button.
Select Get Versions. All available subsystems will be shown with their firmware versions and their
CAN IDs.
Select the head processor for the relevant gantry e.g. gantry 1.
Open the GSMfolder.
CAUTION
Direct CAN bus commands should only be used by specially trained and qualified service
technicians.
NOTICE
When you want to be read out the board type ID‘s via the menu gripper, the BIOS and
application-software have to downloaded on the TQM module. Reading out is currently only
possible via the Gripper menu. to write the ID‘s on the EEPROM you need CAN Bus
commands.
Change Properties Change Machine
Configuration
Open Subsystem Control
Center
Communication and Control
Board IDs Reading the Board IDs out of the EEPROM
141 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Subsystem control center
Double-click on Gripper and the following dialog box will open:
Dialog head processor gripper
Select the board to be checked Off then select the button Get EEPROM.