00194614-08 Trainingsdoku. SG X-Serie_X4i SW70x (AL2)_EN.pdf - 第258页

C&P20A Nozzle Changer for C&P20A Nozzle changer Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 258 When could you need to set the jaws? ▪ When error messages are issued by the sta tion software (e.g. r eferenc…

100%1 / 522
C&P20A
Settings Setting the Jaws for C&P20A
257 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Nozzle stati on
7.5.2.1 Nozzle station
The height of the nozzle reject unit must be set to 140.0 +\-0.3 mm. Measurement follows the same
procedure as that for the nozzle changer .
See also
7.5.2 Setting the Nozzle Changer for C&P20A [ ➙ 256]
Setting the Jaws for C&P 20A
7.5.3 Setting the Jaws for C&P20A
Basics
7.5.3.1 Basics
The jaws need to be correctly set, to ensure that the bridge between the raceway and jaws is accurate.
The correct height between the raceway and jaws is achieved by determining the zero point correction
value for the Z axis.
When fitting the jaws at the Z axis, it is possible to rotate the jaws. With the help of the setting gauge,
the correct angle of the jaws to the raceway can be fixed.
NOTICE
Fitting the nozzle changer
When fitting the nozzle changer, make sure that the component reject tray can be removed.
Make sure that the screws you are using are not too long, as these might jam the reject tray.
The C&P20 reject unit is equipped with a device for
checking the seat of the nozzles on the segments, after a
nozzle change. The nozzle station also features an air
blast valve, which removes the components externally
with a blast of air. If components are not rejected via the
blast air pulse by the pressure control valve, the
placement head will automatically move to the nozzle
station to reject the components there.
Legend
1. Check nozzle seat
2. Nozzle reject
NOTICE
This service task requires the use of a special tool and may therefore only be performed by
specially trained SIPLACE service technicians. The procedure is described in a separate
manual.
C&P20A
Nozzle Changer for C&P20A Nozzle changer
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 258
When could you need to set the jaws?
When error messages are issued by the station software (e.g. reference run).
If the determination of the Z and star zero point correction is not successful, you will need to have
the position of the jaws checked by the SIPLACE Service team.
When replacing or dismantling the Z drive unit, as the jaws are not aligned to the raceway.
When dismantling the component sensor and star frame
Nozzle changer
7.6 Nozzle changer
The nozzle changer enables the nozzle configuration to be changed quickly, thus allowing the placement
head to be quickly adapted to the needs of the placement process.
Nozzle Changer for C&P20A
7.6.1 Nozzle Changer for C&P20A
Main view - nozzle changer and nozzle magazine
Raceway with Z axis
Legend
1. Raceway
2. Ball bearing on segment
3. Snap jaws
4. Light barrier down
5. Bridge raceway – jaws, left
6. Bridge raceway – jaws, right
C&P20A
Nozzle changer Nozzle Changer for C&P20A
259 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Legend
The new nozzle changer carrier can be used for both the C&P20A and the CPP heads, with the
corresponding magazines. Therefore, the nozzle changer does not need to be exchanged for the head
modularity between the C&P20A and CPP head.
The nozzle changer consists of six magazines, each with twelve nozzle garages. Each nozzle garage
can be configured with different nozzle types. Each magazine is clamped on the basic nozzle changer
body with 4 push buttons and two centering pins. The nozzle magazines are opened or closed with the
help of the pneumatic valves. Each magazine can be individually released and removed by pressing the
lever (one on each magazine). There are three microswitches beneath each magazine. These monitor
the correct position and correct magazine type. If all magazines have correctly engaged on the basic
body, this will be shown by a green LED. Since this microswitch is integrated into the safety circuit, the
machine can not be started unless the magazines are installed.
Nozzle Changer
7.6.1.1 Nozzle Changer
1. Nozzle changer frame
2. Push button for NC magazine release.
3. Actuator to open and close the NC magazines via software.
4. Monitor NC magazines, switches 1, 2 & 3.
5. Spring pins to mount the NC magazines.
1 Nozzle changer basic unit 3 Magazine release lever
2 Magazine
NOTICE
X4I
Nozzle changer magazines 1 and 4 cannot be used at locations 2 and 4 of the X4I.
Replacement magazines can be prepared here and then configured quickly with the SW.