00194614-08 Trainingsdoku. SG X-Serie_X4i SW70x (AL2)_EN.pdf - 第471页
MTC2 MTC2 Calibration and Settings SITEST Calibration Flow Ch arts 471 Student Guide SIPLACE X-Serie and X4I SW70x (AL2) ► Open the cover and move the tray back in th e direction t o the l ifting axes ► Then move the tra…

MTC2
SITEST Calibration Flow Charts MTC2 Calibration and Settings
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 470
1b. Manuall Input of the Zero point c orrection
1b. Manuall Input of the Zero point correction
During calibration, the ZPC value is automatically entered in the Removal position cassette 1
line of the machine data.
Is this value to big, it is not possible to calibrate the max. and min. travel range of the feed axis.
Reason: The travel range will be calculated from the row Zero point correction . If this line shows
the value zero, the feed axis will move to the end position switch during measurement.
Solution: Enter the calibrated value for Removal position cassette 1 in the Zero point
correction line of the machine data. In the Position of removal Position cassette 1 line,
enter the value zero .
SITEST:
► MTC --> Axes
► Choose feed axis
► Select Positions
Example: Input machine data tower 1
Example: Input machine data tower 2
► After the manuall Inputs, check the Zero point correction again.
2a. Trans fer position of t he Tower 1 XL WTC
2a. Transfer position of the Tower 1 XL WTC
► Select Teach transfer position.
When you press the button to calibrate the Transfer position the tray moves approx. 5mm outside of the
feed axis.
CAUTION
If you have confirmed the calibration with OK in this situation, you will have calculated an
incorrect transfer position, which will lead to an incorrect pickup position for the Twin head.

MTC2
MTC2 Calibration and Settings SITEST Calibration Flow Charts
471 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
► Open the cover and move the tray back in the direction to the lifting axes
► Then move the tray back in the direction to the machine and stop so that the plastic edge comes into
line with outer edge of the frame from the feed axis. You must do this in one step.
If the tray has been moved out with the feed axis, push it back in again and try to align it with the feed
axis frame in one step. This eliminates the tolerance between the driver and the tray gap and means
that you do not need to enter a pickup offset in the programming system.
2b. Transfer position of the Tower 2 WTC
2b. Transfer position of the Tower 2 WTC
Select Teach transfer position, the tray will move out and come to a stop approx. 5 mm before
the feed axis ends.
► Open the cover.
► Move the tray in the direction of the machine and stop so that the plastic edge of the tray comes into
line with the frame of the feed axis.
► You must do this in one step.
If the tray has been moved out with the feed axis, push it back in again and try to align it with the feed
axis frame in one step. This eliminates the tolerance between the driver and the tray gap and means
that you do not need to enter a pickup offset in the programming system.
During the production the trays move a different way to her pick up position but the Y Position of the
machinen (pick up postion) of both trays is the same.
Transfer position XL tray
Legend
1. Plastic edge of the WTC XL
2. Edge of the frame from the MTC
CAUTION
If you have confirmed the calibration with OK in this situation, you will have calculated an
incorrect transfer position, which will lead to an incorrect pickup position for the Twin head.
Transfer position JEDEC tray
Legend
1. Plastic edge of the WTC
2. Edge of the frame from the MTC

MTC2
SITEST Calibration Flow Charts MTC2 Calibration and Settings
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 472
Overview "calibration of feed axes 1/2"