00194614-08 Trainingsdoku. SG X-Serie_X4i SW70x (AL2)_EN.pdf - 第401页

Modular Conveyor Conveyor Settings B oard Clamping Functions 401 Student Guide SIPLACE X-Serie and X4I SW70x (AL2) ► To check whether the boar d clampi ng is functionin g properly, cl amp a board with t he lifting table.…

100%1 / 522
Modular Conveyor
Board Clamping Functions Conveyor Settings
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 400
Setting B oard Clamping
11.3.7.1 Setting Board Clamping
Setting t he Board Clamping
11.3.7.2 Setting the Board Clamping
Setting actuator
Legend
1. Setting gauge for actuator [03049740-xx]
2. Actuator
3. Drilling, for fixing the actuator screws, when the
gauge is fitted
If the conveyor control issues the error Clamping
error conveyor, you need to check the distance from
the lifting table actuator to the upper edge of the conveyor
belt.
Use the setting gauge to check and adjust the actuator.
The distance from the clamping actuator (lifting table) to
the top edge of the belt should be 94.0 mm at all four
contact points. (see diagram)
NOTICE
This setting should only be made if there are problems with the clamping.
Modular Conveyor
Conveyor Settings Board Clamping Functions
401 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
To check whether the board clamping is functioning properly, clamp a board with the lifting table.
Then check whether the board is clamped tightly on the side.
Tools
Setting (single and dual conveyor)
The terminal strip may need to be modified, depending on the machine type. As the S27 only has a
maximum clamping area of 74 mm, the terminal strip needs to be fitted on the correct side. The
terminal strip for X series, HS-60 and D series machines needs to be set to 94 mm. Fit the terminal
strip accordingly on the gauge.
The gauge is inserted between the actuator and the clamp.
The actuator can now be released, moved down and then tightened again through the holes
provided.
Quad lane conveyor settings
For initial setting, follow the procedure used for the single and dual conveyors (see above). Make
sure that the long terminal strip [03076698-xx] is fitted on the 94 mm side of the "Adjust gauge
actuator cpl.
As two boards are clamped with the same lifting table, you need to check the clamping play for each
of the single conveyors.
The clamping actuators are delivered with a basic setting of 94.2 mm to the top edge of the conveyor
belt.
If problems occur during board clamping (board partially or fully loose), you will need to reset the
clamp.
The cause of this problem is that there are a total of 6 actuators on 3 conveyor edges. If these are
not set accurately enough (they do not form a level), up to 3 actuators might have been set
incorrectly.These then need to be adjusted.
The clamping function is set with the "Adjust gauge
actuator cpl" [03049740-xx].
Terminal strip for S27, HS-60, HF, X2, X3, X4
[03049739-xx]
Long terminal strip for X4I [03076698-xx]
Modular Conveyor
Board Clamping Functions Conveyor Settings
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 402
Legend
Procedure
A) Checking the clamping play:
Move the lifting table upwards, without the board.
With the aid of a 0.1 mm feeler gauge, check the gap between the conveyor belt and the clamp (see
graphic above).
If the gap is greater than 0.1 mm, the determined distance between the belt and the clamping edge
on the actuator must be reset.
To do this, add the current distance between the actuator and the clamping plate to the distance
between the belt and the clamping edge!
Move the lifting table down again.
(1) Conveyor belt play on the lower edge of the
clamp
(1) Distance 94.2 mm.
NOTICE
The play between the terminal strip and the upper edge of the conveyor belt may not be more
than 0.1 mm.