Energy and Compressed Air Supply Switch On Sequence Pneumatic Units Pneumatic System Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 176 Switch On Sequence Pn eumatic U nits 5.3.3 Switch On Seque nce Pneumatic Units Sw…

100%1 / 522
Energy and Compressed Air Supply
Pneumatic System Overview Pneumatic System
175 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Overview Pneuma tic System
5.3.2 Overview Pneumatic System
The compressed air with 5-10 bar passes through the filter and is split into 2 main paths. 1st path is into
the main regulator and 2nd. path is into the proportional valve.
path 1: proportional valve X58 for regulating 5.0 +0.1 bar output (automatically adjusted)
C&P (input vacuum generator head 4.6 +0.1)
Twin head segment 1 (input vacuum generator head 4.6 +0.1))
Twin head segment 2 (input vacuum generator head 4.6 +0.1))
path 2: Main valve X59 for regulating 5 +0.1 bar (manually adjusted)
Docking unit for changeover table
Conveyor (width adjustment and lifting table)
Regulator for manually adjusting the air pressure used for bulkcase and nozzle changer, reduced to
2.5 +-0.5 bar
Safety valve X60 for tape cutter and conveyor
Energy and Compressed Air Supply
Switch On Sequence Pneumatic Units Pneumatic System
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 176
Switch On Sequence Pneumatic Units
5.3.3 Switch On Sequence Pneumatic Units
Switch on sequence for pneumatic units
Main Valve X 59 for Mach ine Components
5.3.4 Main Valve X59 for Machine Components
After the machine is switched on with the main switch, the valve is powered and air runs into the system.
Opening the covers has no effect on the supply of compressed air. The valve will only close if the voltage
supply fails or if the machine is switched off, in which case the docking unit at the changeover table and
the tape cutter 1-4, plus the PCB conveyor will no longer be supplied with compressed air. The valve is
controlled by relay K1, located in sector 4 (subdistributor). If the pressure falls below 4.5 bar, the CAN
bus will issue a signal.
The pressure for this 5/2 valve is manually adjusted by a regulator to 5 +0.1 bar.
NOTICE
Prop. valve X58, controlled by relay K2, is immediately powered with machine ON. After
performing the reference run, the valve can be switched off via the software (default setting:
2 minutes).
Energy and Compressed Air Supply
Pneumatic System Proportional Valve, Proportional Regulator X58
177 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Proportional Valve, Proportional Regulator X58
5.3.5 Proportional Valve, Proportional Regulator X58
When switching the machine on at the main switch, air is supplied to all placement heads.
After the reference run is performed, the air can be switched off by the software after a certain time (as
standard 2 min.) and air will stop flowing through the vacuum system of the placement heads.
The X58 proportionate valve regulates the compressed air to 4.8 +0.1 bar for the placement head.
Included within this regulator block is a pressure sensor which monitors the outgoing air pressure. If the
pressure falls below 4.5 bar, the CAN bus will issue a signal. The valve is controlled by relay K2, located
in section 2, main distributor.
proportional valve X59 ON/OFF process