00194614-08 Trainingsdoku. SG X-Serie_X4i SW70x (AL2)_EN.pdf - 第491页
MTC2 MTC2 Calibration and Settings Machine Data 491 Student Guide SIPLACE X-Serie and X4I SW70x (AL2) Machine parameters for t ower 1 13.3.6.2 Machine parameters for tower 1 Machine pa rameters for t he lifting a xis on …

MTC2
Machine Data MTC2 Calibration and Settings
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 490
Voltage distributor termin al X01
13.3.5.3 Voltage distributor terminal X01
Motor Circuit Breaker
13.3.5.4 Motor Circuit Breaker
Machine Data
13.3.6 Machine Data
General machine parameters
13.3.6.1 General machine parameters
Software version: Date 11.2004
Serial number, MTC2: 214
Delta fiducial transfer position: 10000
Voltage distributor terminal X01
Legend
1. Bridges on the voltage distributor terminal X01
► Removing the three bridges between 2-3, 6-7 and 10-
11.
► Connect the six bridges between 1-2, 3-4, 5-6, 7-8, 9-
10 and 11-12.
Motor Circuit Breaker
Legend
1. Rotary regulator of the motor protection switch
► It is always 3.5 A.
NOTICE
The machine parameters listed are only an example of a data record. The individual values can
be different for each MTC2 .
WARNING
Incorrectly set machine data can result in a crash between the lifting and feed axes or at the
limit positions of these axes.
MTC2
MTC2 Calibration and Settings Machine Data
491 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Machine parameters for t ower 1
13.3.6.2 Machine parameters for tower 1
Machine pa rameters for t he lifting a xis on tower 1
Machine parameters for the lifting axis on tower 1
Positions
▪ Offset, zero position: -500.300 mm
▪ Position of operator removal position, cassette 1: 0 mm
▪ Position of operator removal position, cassette 2: 103.150 mm
▪ Position of operator removal position, cassette 3: 206.250 mm
▪ Position of operator removal position, cassette 4: 309.450 mm
▪ Position of operator removal position, cassette 5: 412.600 mm
▪ Position of WTC removal position, cassette 1: 28.300 mm
▪ Position of WTC removal position, cassette 2: 131.500 mm
▪ Position of WTC removal position, cassette 3: 234.500 mm
▪ Position of WTC removal position, cassette 4: 337.800 mm
▪ Position of WTC removal position, cassette 5: 440.950 mm
▪ Minimum position: -3.233 mm
▪ Maximum position: 573.472 mm
▪ Service position: 165.000 mm
Travel parameters
▪ Default speed, WTC: 50
▪ Default acceleration, WTC: 50
▪ Acceleration, lower threshold value: 1
▪ Acceleration, upper threshold value: 50
▪ Acceleration, axis command: 50
▪ Acceleration, axis command: 50
Machine pa rameters, fee d axis, tower 1
Machine parameters, feed axis, tower 1
Positions
▪ Position of WTC removal position, cassette 1: 0 mm
▪ Position of WTC removal position, cassette 2: -0.180 mm
▪ Position of WTC removal position, cassette 3: -0.220 mm
▪ Position of WTC removal position, cassette 4: 0.230 mm
▪ Position of WTC removal position, cassette 5: -0.320 mm
▪ Offset, zero position: -11.350 mm
▪ Component transfer position: 646.500 mm
▪ Minimum position: -3.389 mm
▪ Maximum position: 652.548 mm
▪ Service position: 249.999 mm
Travel parameters
▪ Default speed, moving WTC out: 150
▪ Default speed, moving WTC in: 150
▪ Default acceleration, WTC: 100
MTC2
Machine Data MTC2 Calibration and Settings
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 492
▪ Acceleration, lower threshold value: 1
▪ Acceleration, upper threshold value: 150
▪ Acceleration, axis command: 50
▪ Acceleration, axis command: 50
Machine parameters for t ower 2
13.3.6.3 Machine parameters for tower 2
Machine pa rameters for t he lifting a xis on tower 2
Machine parameters for the lifting axis on tower 2
▪ Offset, zero position: -566.420 mm
▪ Position of operator removal position, cassette 1: 0 mm
▪ Position of operator removal position, cassette 2: 143.400 mm
▪ Position of operator removal position, cassette 3: 286.950 mm
▪ Position of operator removal position, cassette 4: 430.600 mm
▪ Position of WTC removal position, cassette 1: 23.800 mm
▪ Position of WTC removal position, cassette 2: 167.800 mm
▪ Position of WTC removal position, cassette 3: 311.350 mm
▪ Position of WTC removal position, cassette 4: 454.650 mm
▪ Minimum position: -3.939 mm
▪ Maximum position: 573.509 mm
▪ Service position: 165.000 mm
Travel parameters
▪ Default speed, WTC: 50
▪ Default acceleration, WTC: 50
▪ Acceleration, lower threshold value: 1
▪ Acceleration, upper threshold value: 50
▪ Acceleration, axis command: 50
▪ Acceleration, axis command: 50
Machine pa rameters, fee d axis, tower 2
Machine parameters, feed axis, tower 2
▪ Position of WTC removal position, cassette 1: 0 mm
▪ Position of WTC removal position, cassette 2: 0.100 mm
▪ Position of WTC removal position, cassette 3: 0.100 mm
▪ Position of WTC removal position, cassette 4: 0.050 mm
▪ Offset, zero position: -6.350 mm
▪ Component transfer position: 647.100 mm
▪ Minimum position: -10.204 mm
▪ Maximum position: 647.706 mm
▪ Service position: 249.999 mm
Travel parameters
▪ Default speed, moving WTC out: 200
▪ Default speed, moving WTC in: 200
▪ Default acceleration, WTC: 100
▪ Acceleration, lower threshold value: 1
▪ Acceleration, upper threshold value: 150
▪ Acceleration, axis command: 50