00194614-08 Trainingsdoku. SG X-Serie_X4i SW70x (AL2)_EN.pdf - 第350页
Component Handling Changeover Table with One Hand O peration - Function Changeover T able Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 350 Setting th e Pneumat ic Cylind er 10.1.3.3 Setting the Pneumatic Cylinder Th…

Component Handling
Changeover Table Changeover Table with One Hand Operation - Function
349 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Dummy Feeder on the X4I
10.1.2.1 Dummy Feeder on the X4I
Changeover Table with One Hand Operation - Function
10.1.3 Changeover Table with One Hand Operation - Function
Docking
10.1.3.1 Docking
The docking process can only be performed when the machine is on, compressed air is supplied to the
machine and the safety covers are closed.
To dock the changeover table, push the table as far as possible up to the feed device and press the
button on the machine. On the left and right from the empty tape duct are two centering pins to center
the COT for the final correct pick up position.
The feeder contact plate is raised by two pneumatic cylinders and cam disks while, at the same time, the
entire changeover table is pulled into the machine.
Undocking
10.1.3.2 Undocking
To undock, make sure the compressed air is switched on and the protective cover is open (control
system off) and then press the button on the machine frame. The changeover table is released by the
feed device and is pushed out and lowered by two additional pneumatic cylinders, fixed to the left and
right of the empty tape duct. The COT electrical and pneumatic supply will be automatically disconnected
from the machine. When you press the button on X tables, the system first logs off all feeders in the
software. When machine is OFF:
When the machine is switched off or if there is no compressed air supply, the changeover table can be
easily pulled out of the machine by taking hold of the handles.
CAUTION
The 6 inner tracks can not be reached at locations 2 and 4 of the X4I. A dummy feeder is
therefore automatically inserted here. This also contains the position fiducial for calibration of
the tables.

Component Handling
Changeover Table with One Hand Operation - Function Changeover Table
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 350
Setting the Pneumatic Cylinder
10.1.3.3 Setting the Pneumatic Cylinder
The movement of the cam disks at the docking unit can be individually set at the valves of the two
cylinders.
Setting the pneumatic cylinders at the docking unit
Centering pin and pneumatic cylinder at the left and right
of the COT.
Legend
1. Centering Pin for the table plate
2. Cylinder pushing out the COT at undocking
NOTICE
When setting the pneumatic cylinders, make sure that the component trolley is pulled into the
docking unit parallel. The docking and undocking process of the changeover table should be
set to approx. 2 seconds.

Component Handling
Changeover Table Changeover Table with One Hand Operation - Function
351 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Position ing the D ocking Unit in t he Machine
10.1.3.4 Positioning the Docking Unit in the Machine
Positioning the docking unit
SIPLACE X4I
1. Gantry 1
2. Gantry 2
3. Gantry 3
4. Gantry 4
T = transport direction
The docking units can be installed at three different
positions in the machine for each location. The position of
the docking unit depends on the machine type and the
head configuration. Gantries 2 and 4 have been rotated
in the SIPLACE X4I machine. This means that the
docking units at all four locations are mounted in position
3. This creates short travel ranges between the feeders
and the board.