MTC2 Adjustments feed axes MTC2 Calibration and Settings Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 486 Checkin g and se tting the handle sensors Checking and setting the handle sensors Checking and setting the WT…

100%1 / 522
MTC2
MTC2 Calibration and Settings Adjustments feed axes
485 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Light barriers on the feed axes
Legend
Tools and Equipment
Tools and Equipment
Adjustment gauge, crash light barriers (03021679-01)
1 set of Allen keys
Preparat ions
Preparations
Move the feed axis into the zero position --> „Check the zero point“.
1 Handle sensor 3 Crash light barriers
2 WTC safety query
MTC2
Adjustments feed axes MTC2 Calibration and Settings
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 486
Checkin g and se tting the handle sensors
Checking and setting the handle sensors
Checking and setting the WTC safety query
Checking and setting the WTC safety query
Checking and setting the handle sensors
NOTICE! The handle sensors each comprise a
reflecting light barrier which can detect the handle of the
WTC or the side of the handle of the WTC XL. An LED
indicates the switching status of the sensor.
Legend
1. Reflecting light barriers of the handle sensors
2. Mounting plates with clamping screws
3. LEDs
Unscrew the clamping screws of the mounting plate.
Move the mounting plate in the direction of the WTC
until the reflecting light barrier responds (the LED will
change its status). Fix the plate in place there.
Ensure that the status of the LED remains the same
when you move the locked WTC. If necessary, move
the mounting plate a little further in the direction of the
WTC.
Firmly tighten the clamping screws.
Checking and setting the WTC safety queries
Legend
1. Light barrier for the WTC safety query for tower 1
2. Light barrier for the WTC safety query for tower 2
3. Light barrier holder with clamping screws
NOTICE
The WTC safety queries each comprise a light barrier which is interrupted by the front edge of
the WTC or the WTC XL. Two LEDs indicate the switching status of the sensor.
MTC2
MTC2 Calibration and Settings Adjustments feed axes
487 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Unscrew the clamping screws on the middle holder and move it by the following fixed adjustment
amounts (see ):
Tower 1, left side: 3 mm
Tower 1, right side = tower 2, left side = 4 mm
Tower 2, right side: 5.5 mm
Ensure that the status of the LEDs remains the same when you move the locked WTCs. If necessary,
move the holders a little further away from the front edge of the WTCs.
Firmly tighten all clamping screws and varnish them when they have been set.
Checking an d Setting the Crash Light B arriers
Checking and Setting the Crash Light Barriers
Place the adjustment gauge for the crash light barriers along of a empty WPC onto the rail of the
feed axis for tower 1.
Unscrew the clamping screws of the holder for tower 1 and the middle holder (base section) and
place the bottom light barrier pair onto the middle of the gauge. Ensure that the holders do not jam
in their guide.
Firmly tighten the clamping screws. Ensure that the holders cannot be moved or turned any more.
At this setting, the bottom light barrier pair should still just shine through at a height of
12.35 mm + 0.05 mm and no longer shine through at a height of 12.45 mm + 0.05 mm. (dimensions
in diagram)
NOTICE
Make the settings for the feed axis of tower 1 first and then the feed axis of tower 2.
The light barrier holder in the middle accepts the light barriers for both axes but cannot be set
separately. When making settings, both the holder for the sender and the holder for the receiver
of the light barrier pairs must be moved.
CAUTION
The following must be observed for a functional test on the light barrier setting:
- Light barriers must not respond when the lifting axes are moved. When a preliminary setting
has been made, the lifting axis must therefore be moved in 0.1 mm steps over a distance
corresponding to the height of a WTC next to the light barrier to test the setting.
- If the light barrier responds, the emergency stop function is triggered. The emergency stop
status can only be reset, however, when the receiver receives a signal from the transmitter
again.
Loosen the clamping screws on the light barrier holder (transmitter and receiver). Move them
both in the direction of the feed track (away from the tower) until the receiver’s status indicator
switches from red to green. When moving the lifting axis, ensure that the front edge of the WTC
is positioned within the capture area (chamfer) of the adjustment gauge. When moving the
lifting axis, ensure that the front edge of the WTC is positioned within the capture area (chamfer)
of the adjustment gauge Checking and setting the crash light barriers.
NOTICE
The crash light barriers each comprise a light barrier which is activated by a waffle pack tray of
a specific height and is interrupted by a protruding component. Two LEDs indicate the switching
status of the sensor.
NOTICE
Make the settings for the feed axis of tower 1 first and then the feed axis of tower 2.
The light barrier holder in the middle accepts the light barriers for both axes but can be set
separately (it comprises a base section and a movable section). When making settings, both
the holder for the sender and the holder for the receiver of the light barrier pairs must be moved.