00194614-08 Trainingsdoku. SG X-Serie_X4i SW70x (AL2)_EN.pdf - 第466页

MTC2 Calibration sequence in general MTC2 Calibration and Settings Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 466 ▪ Disengaging mechanism The disengaging mechanism e nable s the driver to engage with and disengage…

100%1 / 522
MTC2
MTC2 Calibration and Settings Calibration sequence in general
465 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Terms of cal ibration lifting axes
13.3.1.1 Terms of calibration lifting axes
Zero offset (zero position)
The zero offset is used to define the refill position of cassette 1. The zero offset is the difference
between the physical home position of the lifting axis and the refill position of cassette 1.
Refill positions (operator removal positions)
At the refill positions of cassettes 1 - 5 (tower 2: cassette 1 - 4), the cassettes can be removed from
the tower by the operator. The relevant cassette is located at the level of the tabletop which is used
as an aid in removal and feeding.
Transfer positions (WTC transfer positions)
At the transfer positions of WTC 1 - 5 (tower 2: WTCs 1 - 4) the lowest WTC in each cassette can
be moved onto the rails of the feed axis by the driver.
min. and max. position
The end positions of an axis are reached when contact is made with the relevant limit switch. The
value determined here is used as a safety constraint when values are entered in the service menu
of the controller software.
Guide rails and stopper bars
The guide rails and stopper bars ensure that operation is only restored after refilling if the cassettes
and WTCs have been inserted correctly. They prevent them from inadvertently straying out of the
locked position during operation.
Cassette guide rails
The cassette guide rails guide cassettes onto the table tops during refilling.
Terms of cal ibration feed axes
13.3.1.2 Terms of calibration feed axes
Zero offset (zero position)
The zero offset is used to define the removal position of WTC 1. The zero offset is the difference
between the physical home position of the feed axis and the position of the driver at which it is
inserted in the WTC on level 1.
Removal positions (WTC removal positions)
At the removal positions of WTC 1 - 5 (tower 2: WTCs 1 - 4), the driver can be inserted into the lowest
WTC in each cassette and move this into the transfer position.
Transfer position (component transfer position)
The transfer position is the position of the feed axis at which components can be picked up by the
placement head of the SIPLACE station without a correction value. The position of the waffle pack
tray reference edges in relation to the reference holes of the MTC2 is stored in the line computer.
min. and max. position
The end positions of an axis are reached when contact is made with the relevant limit switch. The
value determined here is used as a safety constraint when values are entered in the service menu
of the controller software. If a limit switch is overrun during operation, the relevant axis is stopped
immediately to prevent a crash from occurring.
Handle sensor, WTC safety query and crash light barriers
The handle sensor checks the handle of the WTC in the removal position and thus the position of
the WTC which has been moved back, to prevent a crash from occurring.
The WTC safety query checks the correct position of the WTC which has been moved back before
the lifting axis is moved, to prevent a crash from occurring.
Depending on the height of the waffle pack tray which has been set up, the crash light barriers check
the height of the WTC which is moving back, to prevent a crash from occurring in the cassette.
CAUTION
Incorrectly set machine data can result in a crash between the lifting and feed axes or at the
limit positions of these axes.
MTC2
Calibration sequence in general MTC2 Calibration and Settings
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 466
Disengaging mechanism
The disengaging mechanism enables the driver to engage with and disengage from the WTC.
CAUTION
Incorrectly set machine data can result in a crash between the lifting and feed axes or at the
limit positions of these axes.
NOTICE
For calibrating the zero point correction and transfer position at the feed axis, read the notes in
"13.3.2.2 Feed axis" [ ➙ 468].
MTC2
MTC2 Calibration and Settings SITEST Calibration Flow Charts
467 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
SITEST Cali bration Flow C harts
13.3.2 SITEST Calibration Flow Charts
Lifting axis
13.3.2.1 Lifting axis
Overview "Calibration Lifting axes"