Energy and Compressed Air Supply
Power supply Main distributor (X series from Ma. No. B326)
153 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Handing over constituent (A2): Designation X30ra and X31ra
Placement head gantry 1: Designation a+
Gantry distributor: 00 353593 aa
Gantry interface: 00 363330 ab
Head interface: 03000900 ac
Vision board: 03 321469 au
Placement head gantry 3: Designation b+ / c+
(in machines up to MA No. xx the designation is b+ /
in machines from MA No. xx the designation is c+)
Gantry distributor: 00 353593 ba
Gantry interface: 00 363330 bb
Head interface: 03000900 bc
Vision board: 03 321469 bu
Placement head gantry 4: Designation d+
Gantry distributor: 00 353593 da
Gantry interface: 00 363330 db
Head interface: 03000900 dc;
Vision board: 03 321469 du;
Computer unit: X1p+
Main distrib utor (X seri es from Ma. N o. B326)
5.2.2 Main distributor (X series from Ma. No. B326)
Main distributor (X series from Ma. No. B326, X4I)
[03046225-xx]
Legend:
1. Terminal strip X1qa (GND, +5 V, +15 V, -15 V,
+24 V, various signals)
2. DC/DC converter for illumination of all cameras
(PCB, component and stationary cameras) in
placement area 2
3. Socket for Interface 1-Wire CAT5
4. CAN-Bus I/O module (A1)
5. Connector block (connection X2qa - X6qa, X71qa -
X74qa and X9qa - X24qa)
6. Relay K2 switches the compressed air supply for the
placement heads off (can be configured in the station
software)
Energy and Compressed Air Supply
Subdistributor (X Series from Ma. No. B326) Power supply
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 154
Subdistributo r (X Series from Ma. No. B326)
5.2.3 Subdistributor (X Series from Ma. No. B326)
Power supply
5.2.4 Power supply
The main power supply unit is mounted on a compact slide-in module, and located on the left side of the
machine. When viewed from the outside only the red main power switch is visible.
A lockable door prevents access to the power supply.
With the open cover, the state of the following protective devices can be quite easily monitored.
Motor Circuit Breaker
Main contactor
Safety relay
Power circuit breaker
Protective contactor combination (SSK)
The following work must be performed to adjust the power supply to the country-specific requirements
(see also the conversion instructions for power supplies):
1. Replace the motor protecting switch
2. Replace the power supply cable (country-specific)
3. At the primary end of transformer T1, the terminal connectors (U, V, W) must be reconnected to fulfill
the country-specific voltage requirements.
4. Reconnect the connector on the inrush limitation board transformer.
Subdistributor (X Series from Ma. No. B326, X4I)
[03046226-xx]
Legend:
1. Terminal strip X1ra (GND,+5 V,+15 V,-
15 V,+24 V,+52 V, various signals)
2. DC/DC distributor for illumination of all cameras
(PCB, component and stationary cameras) in
placement area 1
3. Socket for Interface 1-Wire CAT5
4. CAN I/O module (A1)
5. Connector block (connection X3ra - X6ra, X71ra-
X74ra, X10ra - X24ra)
6. F1: Fuse for hood fan
7. K3: Relay for hood fan
8. K1: This relay switches the main valve in the
pneumatic unit.
Energy and Compressed Air Supply
Power supply Power supply
155 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Main power supply
3 phase alternating power is supplied for operation of the SIPLACE X machines. N is only used for the
service socket. The contacts L1/L2/L3/N/PE are below the main power module. The phase L3 is also
fuse-protected for the server socket, via the F1 fuse.
Voltages at the M ain Power Supply
5.2.4.1 Voltages at the Main Power Supply
Assembly Designation Contact Voltages
X100 Main power supply L1, L2, L3 3 x 204 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
X102 service socket L3, N, PE 115 VAC/220 VAC/
230 VAC/240 VAC
Z1 Main power filter L1, L2, L3 3 x 204 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
Q1 Main switch 1, 3, 5 &
2, 4, 6
3 x 204 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
Q2 Motor Circuit Breaker 1, 3, 5 &
2, 4, 6
3 x 204 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
L20 Discharge inductor L1, L2, L3 3 x 204 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC