00194614-08 Trainingsdoku. SG X-Serie_X4i SW70x (AL2)_EN.pdf - 第369页

Component Handling X Feeder Error Messages on X Feeder 369 Student Guide SIPLACE X-Serie and X4I SW70x (AL2) Error Mess ages on X Feeder 10.2.8 Error Messages on X Feeder When the fee der is ready for operation, you will…

100%1 / 522
Component Handling
Operation X Feeder
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 368
Service menu for reference run
Feeder Setti ngs at the Stat ion
10.2.7.15 Feeder Settings at the Station
CAUTION
During the reference run with a tape you have to open the pick up window and no foil in the foil
removal unit and you lost components.
Recommendation: Carry out the reference run with out a tape.
View of feeder settings
The line GUI can be configured in the SIPLACE Pro
programming system, so that correct feeder data are sent
to the machine. For reliable production, we recommend
regularly updating the feeder data for the components, to
avoid incorrect operation of the feeders.
The adjacent diagram shows the correct transmission of
feeder settings from SIPLACE Pro.
If a spanner appears in the feeder status field, this means
that manual settings are needed.
Component Handling
X Feeder Error Messages on X Feeder
369 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Error Messages on X Feeder
10.2.8 Error Messages on X Feeder
When the feeder is ready for operation, you will see a green LED. Warnings and error messages are
shown by orange or red LEDs and a text on the LCD display.
Warnings
View of feeder settings
If the feeder data transfer is disabled in SIPLACE Pro and
if the data from the programming system and the feeder
do not match, a warning will be issued or the fields will be
marked red (see adjacent diagram).
View of feeder settings
The data can now be manually changed using the
buttons in the relevant line.
Display LED
display
Meaning Troubleshooting
Remove Foil
(Folie
entfernen)
Orange Unable to perform the
function selected with the
cover foil stretched tight
(foil rocker is pushed
down).
If the required function is to be
performed, remove the foil from
the toothed wheels and cut it to
relax the foil rocket.
Component Handling
Error Messages on X Feeder X Feeder
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 370
Error messages
Display LED
display
Meaning Troubleshooting
None Red,
flashing
Application software not
present or faulty
software remains in boot
loader.
Reload the application software.
Handle
(Griff)
Red The feeder module has
been logged in but the
removal handle has not yet
been engaged (pushed in).
Push in the handle until it
engages.
Low Voltage
(Unter-
spannung)
Orange 24V supply voltage has not
reached the switching-on
threshold after being
switched on.
Check the voltage supply.
Low Voltage
(Unter-
spannung)
Red 24V supply voltage has
exceeded the switching-on
threshold and has then
collapsed.
Check the voltage supply.
Feed Timeout
TransTimeout
(Zeitfehler beim
Gurttransport-
zyklus)
Red Tape transport cycle was
not completed correctly in
the set time (timeout for
function "Feed").
Is the tape reel trapped in the
container?
Is the component trapped in the
pickup area, between the tape
and the component window?
Once you have solved the
blockage, reinitiate the feed-in
with the arrow buttons. The
feeder module will finish the
faulty feed run and will return to
its correct position.
Foil Torn
(Folie gerissen)
Red Foil was not tensioned
within the prescribed time.
The foil has probably been torn.
Reinsert the foil and re-tension
it.
Foil PeelErr
(Fehler beim
Abziehen der
Folie)
Red Foil has not been correctly
stripped off, although the
tape is being fed in.
The cover foil has probably been
trapped under the pickup
window and therefore not
stripped off properly.
Foil Jam
(Folienstau)
Red Foil motor jammed Toothed wheels blocked by foil?