Collect, Pick and Place Head (CPP) Vacuum System Overview Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 284 Vacuum Syste m Function 8.2.8.1 Vacuum System Function ▪ The pneum atic distribut or (1) sup plies the press…

100%1 / 522
Collect, Pick and Place Head (CPP)
Overview Vacuum System
283 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Vacuum System
8.2.8 Vacuum System
Legend
(1) Compressed air distributor (2) Holding circuit sensor
(3) Rear cover – CPP head (4) Smooth distributor disc
(5) Valve terminal (6) Star frame with DP drives
(7) Holding circuit (8) Silencer
(9) Pressure control valve (digital) (10) Z axis return cylinder
Collect, Pick and Place Head (CPP)
Vacuum System Overview
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 284
Vacuum System Function
8.2.8.1 Vacuum System Function
The pneumatic distributor (1) supplies the pressure control valve (2), the holding circuit (3) and the
return cylinder with 4.5 bar compressed air.
The compressed air is fed directly through the holding circuit (3) to the valve terminal (6). There it is
distributed into 12 channels.
Each channel in the holding circuit can be separately opened or closed with a solenoid valve (7).
The compressed air is fed from the valve terminal to the holding circuit, through the 12 channels. The
vacuum for the holding circuit of all 12 segments is generated there via 12 venturi nozzles.
The vacuum is fed from the holding circuit via the star frame (5) to the nozzle segment (4).
The holding circuit sensor is located in the CPP head cover (8). The holding circuit sensor can be
used to measure the vacuum of any segment which is in the 12 position.
Collect, Pick and Place Head (CPP)
Overview Vacuum System
285 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Picking Up Components
8.2.8.2 Picking Up Components
Placing Components
8.2.8.3 Placing Components
Before the star rotates into the pickup position, the
relevant valve is switched on via the valve terminal.
Vacuum from the holding circuit is now present at the
nozzle.
Once the star has reached the pickup position, the
holding circuit vacuum is strengthened via the pressure
control valve and the component can be picked up.
After the component has been picked up, the
component is held on the nozzle with the help of the
vacuum from the holding circuit.
If the star is in the placement position and the Z down
sensor is enabled, the pressure control valve will
switch over to air bast. This eliminates the holding
circuit vacuum and an air blast of approx. 200 mbar is
present at the nozzle.
The switch on time for max. vacuum/air blast
depends on the settings programmed in the
programming system.
Once the Z axis has reached the top position, the star
continues to turn. The relevant valve is now closed on
the valve terminal. This saves compressed air!