00194614-08 Trainingsdoku. SG X-Serie_X4i SW70x (AL2)_EN.pdf - 第516页
Measuring Equipment and Tools Scope of Delivery Adjustment Aid for C&P DLM [ 00327005-01] Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 516 Adjustment Aid for C&P DLM [003 27005-01] 14.10 Adjustment Aid for C…

Measuring Equipment and Tools
Location Tester Scope of Delivery
515 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Location Tester
14.8 Location Tester
Z End S topper St ar Gauge for C&P6/ 12 [03019865-01]
14.9 Z End Stopper Star Gauge for C&P6/12 [03019865-01]
Application:
The location tester is used to check the feeder
connections at the communication unit of the changeover
table.
Application:
The gauge is used to set the end stop position of the C&P
head Z axis.

Measuring Equipment and Tools
Scope of Delivery Adjustment Aid for C&P DLM [00327005-01]
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 516
Adjustment Aid for C&P DLM [003 27005-01]
14.10 Adjustment Aid for C&P DLM [00327005-01]
Complete set [00327005-01]
1. Gauge for star [00326164-01]
2. Test probe 1.4 mm [00326160-01]
3. Test probe 1.5 mm [00326161-01]
4. Test probe 1.6 mm [00326162-01]
5. Test probe 1.0 mm [00376656-01]
6. Distance gauge [00325445-01]
Measurement tools Application type
Gauge for star Setting the zero point correction for the star
Test probe 1.4 mm Setting the distance between the DP station incremental encoder and the glass
for the sleeve
Test probe 1.5 mm
Test probe 1.6 mm
Test probe 1.0 mm Setting the distance from the Z axis light barrier down to the sleeve shaft
Distance gauge Setting the distance of the valve plunger to the star

Measuring Equipment and Tools
Calibration Tool [03010565-xx] Scope of Delivery
517 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Calibrati on Tool [03010565- xx]
14.11 Calibration Tool [03010565-xx]
Calibrati on Tool [03034148- xx]
14.12 Calibration Tool [03034148-xx]
Calibrati on Nozzle for Twi nHead [03 008862-xx]
14.13 Calibration Nozzle for TwinHead [03008862-xx]
Application:
The calibration tool [03010565-xx] is used for calibration
of the C&P6/12 placement heads, CPP, P&P plus
TwinHead (for D, X and SX series).
Application:
The calibration tool [03034148-xx] is used for the C&P20
and C&P20A placement heads in X series (incl. X4I) and
SX series machines.
Application:
The calibration nozzle is used to calibrate the D axis of
the TwinHead or P&P head.