C&P20A Overview Parts Overview with Function Description 219 Student Guide SIPLACE X-Serie and X4I SW70x (AL2) C&P20A Hea d – E/D Tr ansformer (C ollector Ring) C&P20A Head – E/D Transformer (Collector Ring) …

C&P20A
Parts Overview with Function Description Overview
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 218
Star As sembly
7.2.3.5 Star Assembly
Star Frame
Star Frame
The mechanical E/D transformer (1) consists of a stationary and a rotating part. The 6 sliding contacts
transmit direct voltage (24V/4A), ground and the CAN bus signals (CAN high, CAN low).
Legend
1. Motor shaft
2. Star assembly
3. Screws (3) mounting the star unit to the motor shaft
4. Smoothed distributor disc
The star consists of the star frame, on which all 20 DP
drives are located, the motherboard and the E/D
transformer.
This complete unit is fixed to the motor shaft with three
screws and can be removed for service work after the
raceway has been dismounted.
▪ Above the star you will find the E/D transformer (1) for
supplying energy and data to the DP drives.
▪ The motherboard is located behind the control boards
(2) of the DP drives (3) and is responsible for
controlling and positioning the DP drives.
▪ The control board is plugged into the motherboard.
and is fixed via the two brackets (4).
▪ Two screws fix the complete DP drive unit from
inside, to the star frame.
▪ An index screw (5) ensures that the ED transformer
is correctly positioned during assembly.

C&P20A
Overview Parts Overview with Function Description
219 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
C&P20A Head – E/D Transformer (Collector Ring)
C&P20A Head – E/D Transformer (Collector Ring)
Energy t ransmiss ion
Energy transmission
Comparison - E/D transformer
▪ The new E/D transformer consists of a stationary and
a rotating part.
The three sliding contacts (5) transmit the direct
current voltage (24V/4A).
▪ Communication, in other words the transmission of
CAN Bus signals, is contactless.
▪ Connector (1) (connection to intermediate distributor)
▪ The centering pin (2) fixes the stationary part (4) in
place.
▪ The rotating part (3) is fixed with five screws to the
star carrier. These can be loosened via the service
opening (6).
E/D transformer – energy transmission
▪ Two transmission leads are needed to transmit the
energy supply:
P24V (1) and GND (2).
▪ Another lead (sliding contact) connects the rotating
part and the housing ground (ESD protection (3)).

C&P20A
Parts Overview with Function Description Overview
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 220
Holding Circuit
Holding Circuit
Venturi block
▪ The venturi block consists of 20 small venturi nozzles
is located behind the silencer.
▪ Each venturi nozzle supplies one segment with
vacuum in the hold circuit.
▪ If a segment is in the pickup/placement circuit, the
holding circuit vacuum is increased (for pickup) or
eliminated via air blast (for placement).
Legend
1. Fixture on star frame
2. Silencer fixtures
3. Venturi nozzle - discharged air to the silencer
4. Venturi nozzle - vacuum outlet to the segments
5. Compressed air inlet to the venturi nozzle -
The venturi nozzle inlets have seals.
6. O-ring between venturi block and silencer
Position Designation Item No.
1 Venturi block 03005122-0X
2 O-Ring (6) 03011347-0X