4OM-1603
1-53
4. Maintenance Method : Chap.1
4. Maintenance Method
Periodically clean the vacuum nozzles to maintain reliable and stable component
picks and placement.
•
It is advisable that the nozzles be cleaned at least once a week.
Note
The nozzle for 0402 recommends the cleaning every 3 or 4 days.
•
Change cleaning frequency according to various frequency of use and
accumulation of debris along with certain environmental conditions.
•
When the vacuum suction force weakens or a nozzle constantly fails to pick or
place components, it is required to check the nozzle for debris and cleanliness.
Do not grasp this part strongly during the
nozzle cleaning.
Otherwise, the nozzle may be damaged.
When it is necessary to hold the nozzle firmly,
try to grasp the collar portion.
When a recognition error occurs frequently,
rub the back of the collar approximately
20 times with a toothbrush.
F4A39-1
1202-002

4OM-1603
1-54
4. Maintenance Method : Chap.1
4.1 Cleaning Method of Vacuum Nozzles
Remove Nozzle Filter
Refer to "4.3 Nozzle Filter Removal Procedure"
for details.
Blow air Vacuum Nozzle
Confirm that there is no clog in pick-up hole
Refer to "4.4 Method of Blow air" for details.
Confirm the clog in the top of pick-up hole by
the magnifying glass.
Refer to "4.5 Cleaning of high-speed nozzle
hole part with pin gauge" for details.
Remove Vacuum Nozzle
Refer to "4.2 Method of detaching vacuum
nozzle" for details.
Insert the nozzle filter
Refer to "4.6 Nozzle Filter Insertion Procedure"
for details.
Reference
Reference
Reference
Reference
Reference
F4A39-1a
1202-001

4OM-1603
1-55
4. Maintenance Method : Chap.1
4.2 Method of detaching vacuum nozzle
•
Store the nozzle in the nozzle stocker (housing) through window
navigations and take out the nozzle stocker (housing).
Notice
(a) Do not take out a nozzle from the head by hand. Otherwise, the
nozzle does not conform to the nozzle data.
(b) When the ultrasonic cleaning operation is to be performed
underwater,removethenozzlelter.
Do not use anything other than water for the cleaning.
(c) Demagnetize the vacuum nozzle after the detachment.
Keeptheheadsectionfreeofanymagneticeld.
As an example,
•
Do not bring a magnet close to the head section.
•
Do not bring any demagnetizer to the head section.
Demagnetize the vacuum nozzle each unit.
Reference
Refer to "5. Nozzle Change Window" in "Chapter 6 (Vol. 2)" for the
procedure of nozzle storage.
1202-003