Error ID Error Name, Description, Cause, and Remedy
602501 Teaching Tray Matrix
Error of teaching coplanarity.
-----
602502 Teaching Tray Matrix
Error of XY-axis movement
-----
602503 Teaching Tray Matrix
Time-out in XY-axis movement
-----
602504 Teaching Tray Matrix
Error in Manual Teach
-----
602601 Teaching Coplanarity
Error of teaching coplanarity.
-----
602602 Teaching Coplanarity
Recognition Error
-----
602603 Teaching Coplanarity
Timeout of communication with Coplanarity unit
-----
602701 Teaching Table Offset
Error in Table Offset Teach
-----
602702 Teaching Table Offset
Error of Recognition Command Response. Is P.C.B. taken in correctly?
Please check it.
-----
602801 Teaching position of Support Pin
Error in teaching position of Support Pin
-----
602802 Teaching position of Support Pin
Error in responding Recog command
PleaseconrmthatPinforteachingisarranged.
602803 Teaching position of Support Pin
Time-out of Communication with Recog
-----
602804 Teaching position of Support Pin
Position Offset of Support Pin is out of the permissible value.
-----
602901 Teaching PCB height measured Sensor
Error of teaching PCB height measured Sensor.
-----
602902 Teaching PCB height measured Sensor
Error of responds of Recog command
-----
1109-006

4OM-1603
3-148
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
602903 Teaching PCB height measured Sensor
Time-out of Communication with Recog.
-----
602904 Teaching PCB height measured Sensor
Could not measure Sensor position Offset correctly.
Please retry to adjust PCB height measured Sensor.
602905 Teaching PCB height measured Sensor
Error of measuring PCB height Sensor
-----
602906 Teaching PCB height measured Sensor
Time-out of measuring PCB height Sensor.
-----
602907 Teaching PCB height measured Sensor
The result of PCB height measured Sensor is out of Permission values.
Please retry to adjust PCB height measured Sensor.
602908 Teaching PCB height measured Sensor
Error of processing in Zero Shift of PCB height measured Sensor.
-----
603001 XY Origin teach
Failed to recognize Origin Correction Mark
Modify the teaching position and execute teaching again.
604001 Automatic Teaching on producing operation.
Failed to recognize a nozzle in Head rotation center offset teaching.
-----
604002 Automatic Teaching on producing operation.
Error in recognition command response in Head rotation center offset teaching.
-----
604003 Automatic Teaching on producing operation.
Could not recognize the Standard Mark.
-----
604101 Teaching Placement-Height
Error is detected before starting Detection on the Linear Sensor.(There is a
possibility that the Linear measure Sensor is broken , or Odd Noz is placed)
-----
604102 Teaching Placement-Height
Time-out of [OFF] signal of Linear measure sensor
-----
604103 Teaching Placement-Height
Error in DD-axis
-----
604104 Teaching Placement-Height
Error in NS-axis
-----
604105 Teaching Placement-Height
Error in DD/NS-axis
-----
1109-006

4OM-1603
3-149
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604106 Teaching Placement-Height
Time-out of DD/NS-axis
-----
604107 Teaching Placement-Height
Error in calculating drive wave of HL-axis
-----
604108 Teaching Placement-Height
Error in calculating drive wave of NL-axis
-----
604109 Teaching Placement-Height
Time-out of starting HL/NL-axis movement
-----
60410a Teaching Placement-Height
Time-out of starting HL-axis movement
-----
60410b Teaching Placement-Height
Time-out of starting NL-axis movement
-----
60410c Teaching Placement-Height
Time-outofnishingHL/NL-axismovement
-----
60410d Teaching Placement-Height
Failed in measuring real time of linear measure sensor.
-----
60410e Teaching Placement-Height
ODD Noz is placed on Head, or error is detected during linear measure sensor.
-----
60410f Teaching Placement-Height
Flange of Nozzle is not detected within the predetermine range.(Not E/NR)
Please remeasure the height teach after teaching the head rotation on the angle
axis.
604110 Teaching Placement-Height
Flange of Nozzle is not detected within the predetermine range.(E/NR)
Please remeasure the height teach after teaching the head rotation on the angle
axis.
604111 Teaching Placement-Height
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
604112 Teaching Placement-Height
Program Error
-----
604113 Teaching Placement-Height
Offset is 1mm less than the set value.
-----
604114 Teaching Placement-Height
Offset is 1mm more than the set value.
-----