4OM-1603-007_w.pdf - 第294页

4OM-1603 3-1 19 3. Error IDs and Remedial Procedures : Chap.3 Error ID Error Name, Description, Cause, and Remedy 4b3301 Data Communication Error failed in data expansion There is a possibility of following errors 1. Com…

100%1 / 379
4OM-1603
3-118
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
4b310b Cutter(Servo Error)
Reading Error on permanent memory
Exchange Driver
4b310c Cutter(Servo Error)
CPU Error
Exchange Driver
4b310d Cutter(Servo Error)
Parameter Error
PleaseconrmthechangedParameter
4b310e Cutter(Servo Error)
Alarm code readout failed
-----
4b310f Cutter(Servo Error)
Low driving voltage(Block1)(Feeder Base [ON])
-----
4b3110 Cutter(Servo Error)
Low driving voltage(Block2)(Feeder Base [ON])
-----
4b3111 Cutter(Servo Error)
Low driving voltage(Block1)(Feeder Base [OFF])
-----
4b3112 Cutter(Servo Error)
Low driving voltage(Block2)(Feeder Base [OFF])
-----
4b3201 Servo Motor Error
Error of processing Servo On
-----
4b3202 Servo Motor Error
Time-out of processing Servo On
-----
4b3203 Servo Motor Error
Error of processing Servo Off
-----
4b3204 Servo Motor Error
Time-out of processing Servo Off
-----
4b3205 Servo Motor Error
Time-out of processing Servo On(Block1)
Please restart the machine.
4b3206 Servo Motor Error
Time-out of processing Servo On(Block2)
Please restart the machine.
1109-006
4OM-1603
3-119
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
4b3301 Data Communication Error
failed in data expansion
There is a possibility of following errors
1. Communication Error
2. Data loss
Please contact the service when not repaired even if turns it on again.
4b3401 Nozzle check Error before Pickup(Detected before operating)
It stopped because the remains components on the nozzle or adhering matters on
the linear measure sensor of Light Emitter/Receiver were detected.
TheremainsComponentonanozzleorawandsoilonLightEmitter/Receiverof
Linear measure Sensor could be considered to adhere. Please clean it up.
4b3402 Nozzle check Error before Pickup(Detected before operating)
Error in Communication with Linear measure sensor.
PleaseconrmErrorfromLogRequestScreen(Unitadjustment->Linear
measureSensorScreen).Either,pleaseconrmwhethertheitemsofLS-RLS-
S(Device Check -> List) is Yellow. HLS communication cable could not be
connected and such like things.
4b3403 Nozzle check Error before Pickup(Detected before operating)
Error in Origin moving in HL/NL/L-axis
-----
4b3404 Nozzle check Error before Pickup(Detected before operating)
Error of nozzle check before pick-up
-----
4b3405 Nozzle check Error before Pickup(Detected before operating)
Error in discarding the remains detect component
-----
4b3406 Nozzle check Error before Pickup(Detected before operating)
Error of nozzle check before pick-up(program error)
-----
4b3501 Automatic Zeroing Error
Failed to zeroing automatically
Please restart.
4b3601 Receding Error
Motor Error on receding
-----
4b3602 Receding Error
Time-out on receding
-----
4b3701 Writing Origin position of License nozzle
Linear measure Sensor error is detected before operating.
-----
4b3702 Writing Origin position of License nozzle
Failed in getting Offset data
-----
4b3703 Writing Origin position of License nozzle
Failing in writing origin position of Noz.
-----
1109-006
4OM-1603
3-120
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
4b3801 Bad Mark Sensor Error
Cannot detect Bad Mark normally for Error in Bad Mark Sensor.
Execute adjustment of Bad Mark Sensor
4b3901 Bad Mark Sensor Adj Error
Failed to recog the white of Bad Mark.
-----
4b3902 Bad Mark Sensor Adj Error
Bad Mark Sensor Error, Stability signal is not off.
-----
4b3903 Bad Mark Sensor Adj Error
Bad Mark Sensor Error, Stability signal is not off.
-----
4b3904 Bad Mark Sensor Adj Error
Failed to recog the Black of Bad Mark.
-----
4b3905 Bad Mark Sensor Adj Error
ConditionError.PleaseadjustthewhileofBadMarkrst.
-----
4b3906 Bad Mark Sensor Adj Error
Failed in Level retreat.
-----
4b3907 Bad Mark Sensor Adj Error
Time-out of head moving.
-----
4b3908 Bad Mark Sensor Adj Error
Level retreat starts-up Error
-----
4b3909 Bad Mark Sensor Adj Error
HeadmovingspecicationError
-----
4b390a Bad Mark Sensor Adj Error
Head moving starts Error
-----
4b390b Bad Mark Sensor Adj Error
Parameter Error
-----
4b4001 Damaged cover tape / Cover tape jammed in the storage / Splicing section
peeling off
Alarm Code:E0 - (1)Damaged cover tape/ (2)Cover tape jammed in the storage/
(3)Splicing section peeling off
(1)Conrmwhetherornotthecovertapeissetcorrectly
(2) Please remove the cover tape from the storage section.
(3) Please check the splicing condition if the work performed correctly in the
process.