Error ID Error Name, Description, Cause, and Remedy
60450b Teaching Pickup-Height
Time-out of starting NL-axis movement
-----
60450c Teaching Pickup-Height
Time-outofnishingHL/NL-axismovement
-----
60450d Teaching Pickup-Height
Failed in measuring real time of linear measure sensor.
-----
60450e Teaching Pickup-Height
Error in measuring Linear measure sensor
-----
60450f Teaching Pickup-Height
Flange of Nozzle is not detected within the predetermine range.(Not E/NR)
Please remeasure the height teach after teaching the head rotation on the angle
axis.
604510 Teaching Pickup-Height
Flange of Nozzle is not detected within the predetermine range.(E/NR)
Please remeasure the height teach after teaching the head rotation on the angle
axis.
604511 Teaching Pickup-Height
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
604512 Teaching Pickup-Height
Program Error
-----
604513 Teaching Pickup-Height
Offset is 1mm less than the set value.
-----
604514 Teaching Pickup-Height
Offset is 1mm more than the set value.
-----
604515 Teaching Pickup-Height
The value of Flowmeter is higher than 5.0V.
-----
604516 Teaching Pickup-Height
The value of Flowmeter is lower than 4.7V.
-----
604517 Teaching Pickup-Height
ThereisnomeasureddataofNoz1.ItisnecessarytomeasureNoz1rst.
-----
604518 Teaching Pickup-Height
CannotmeasureitforXY-coordisnotdened.
-----
604519 Teaching Pickup-Height
Error in Flowing Quantity
-----
1109-006

4OM-1603
3-157
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604601 Teaching Height of Glass Jig
Error is detected before starting Detection on Linear Measure Sensor.(There is a
possibility that Linear measure sensor is broken, or Odd Noz is placed.)
-----
604602 Teaching Height of Glass Jig
Time-out of [OFF] signal of Linear measure sensor
-----
604603 Teaching Height of Glass Jig
Error in DD-axis
-----
604604 Teaching Height of Glass Jig
Error in NS-axis
-----
604605 Teaching Height of Glass Jig
Error in DD/NS-axis
-----
604606 Teaching Height of Glass Jig
Time-out of DD/NS-axis
-----
604607 Teaching Height of Glass Jig
Error in calculating drive wave of HL-axis
-----
604608 Teaching Height of Glass Jig
Error in calculating drive wave of NL-axis
-----
604609 Teaching Height of Glass Jig
Time-out of starting HL/NL-axis movement
-----
60460a Teaching Height of Glass Jig
Time-out of starting HL-axis movement
-----
60460b Teaching Height of Glass Jig
Time-out of starting NL-axis movement
-----
60460c Teaching Height of Glass Jig
Time-outofnishingHL/NL-axismovement
-----
60460d Teaching Height of Glass Jig
Failed in measuring real time of linear measure sensor.
-----
60460e Teaching Height of Glass Jig
Error in measuring Linear measure sensor
-----
60460f Teaching Height of Glass Jig
Flange of Nozzle is not detected within the predetermine range.(Not E/NR)
Please remeasure the height teach after teaching the head rotation on the angle
axis.
1109-006

4OM-1603
3-158
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604610 Teaching Height of Glass Jig
Flange of Nozzle is not detected within the predetermine range.(E/NR)
Please remeasure the height teach after teaching the head rotation on the angle
axis.
604611 Teaching Height of Glass Jig
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
604612 Teaching Height of Glass Jig
Program Error
-----
604613 Teaching Height of Glass Jig
Offset is 1mm less than the set value.
-----
604614 Teaching Height of Glass Jig
Offset is 1mm more than the set value.
-----
604615 Teaching Height of Glass Jig
The value of Flowmeter is higher than 5.0V.
-----
604616 Teaching Height of Glass Jig
The value of Flowmeter is lower than 4.7V.
-----
604617 Teaching Height of Glass Jig
ThereisnomeasureddataofNoz1.ItisnecessarytomeasureNoz1rst.
-----
604618 Teaching Height of Glass Jig
CannotmeasureitforXY-coordisnotdened.
-----
604619 Teaching Height of Glass Jig
Error in Flowing Quantity
-----
604701 Teaching Height of Traverse Chute
Error is detected before starting Detection on Linear Measure Sensor.(There is a
possibility that Linear measure sensor is broken, or Odd Noz is placed.)
-----
604702 Teaching Height of Traverse Chute
Time-out of [OFF] signal of Linear measure sensor
-----
604703 Teaching Height of Traverse Chute
Error in DD-axis
-----
604704 Teaching Height of Traverse Chute
Error in NS-axis
-----
604705 Teaching Height of Traverse Chute
Error in DD/NS-axis
-----