4OM-1603-007_w.pdf - 第134页

4OM-1603 2-3 2. Management Information : Chap.2 1012-005 • Remedial Procedure from “Management Information” Window (1) Make a note of the management information. Notice If you forget the Management Information, correct …

100%1 / 379
4OM-1603
2-2
2. Management Information : Chap.2
2. Management Information
2.1 "Management Information" Window
When normal recovery does not occur after a mistake in the machine operation or
an error, the following management information window appears.
[1]
[4]
[3]
[2]
[5]
Example of Management Information F4B2
[1] Management Information
In this window, the management information is displayed.
[2] Management Information Code
In this window, the management information code is displayed.
[3] Display Area A
The outline of the management information is displayed in this area.
[4] Display Area B
The details of the management information are displayed in this area.
[5] [OK] Button
When this button is pressed, the window displayed just prior to the
"Management Information" is returned.
1012-005
4OM-1603
2-3
2. Management Information : Chap.2
1012-005
•
Remedial Procedure from “Management Information” Window
(1) Make a note of the management information.
Notice
If you forget the Management Information, correct recovery can not be
performed. Therefore, make sure to make a note.
(2) Press the [OK] button to return the original window.
(3) Perform the correct recovery based on the Management Information.
4OM-1603
2-4
2. Management Information : Chap.2
2.2 Management Information List
Management
Information Code
Display Area A (The outline of the Management Information)
Display Area B (The details of the Management Information)
010101 Emergency Stop
Press [POWER ON] button to activate Load Power circuit.
010103 Emergency Stop
Emergency Stop switch is pressed. Please cancel it.
010201 Air Pressure Drop
Air Pressure Drop is detected
010401 Safetycoverlockconrm
Please close and lock the safety cover.
010402 Safetycoverlockconrm
Operate after close and lock the safety cover. (LED on)
010403 Safetycoverlockconrm
Operate after close and lock the safety cover.
010404 Safetycoverlockconrm
The safety cover is in unlock. Please complete to unlock and operate it.
010503 Beam XY main circuit OFF
Beam XY main circuit Error
010801 Feederbaseconrm(Block1)
Set the feeder cart(Block1) and connect cable.
010802 Feederbaseconrm(Block1)
Cannot set Feeder Cart downward to detect Elevator Unit(Block1).
Operate after remove it .
010803 Feederbaseconrm(Block1)
Elevator Unit(Block1) is not connected.
Please connect to it with "Unit Exchange Menu".
010804 Feederbaseconrm(Block1)
Batch Connector of Elevator Unit(Block1) is not connected.
Please check connection.
010805 Feederbaseconrm(Block1)
Feeder cart (Block1) is not upper position.
Push Feeder Ready Switch.
010806 Feederbaseconrm(Block1)
Push Feeder Ready SW.
010807 Feederbaseconrm(Block1)
Feeder base power or Feeder power is "OFF". Please press "Feeder Ready"
switch(Block1), and put it up again after putting Feeder Cart(Block1) down.
010901 Feederbaseconrm(Block2)
Set the feeder cart and connect cable.(Block2)
010902 Feederbaseconrm(Block2)
Cannot set Feeder Cart downward to detect Elevator Unit(Block2).
Operate after remove it .
010903 Feederbaseconrm(Block2)
Elevator Unit(Block2) is not connected. Please connect to it with "Unit Exchange
Menu".
1109-006