4OM-1603-007_w.pdf - 第329页
4OM-1603 3-154 3. Error IDs and Remedial Procedures : Chap.3 Error ID Error Name, Description, Cause, and Remedy 604406 T eaching Height of Stocker Master T ime-out of DD/NS-axis ----- 604407 T eaching Height of Stocker …

4OM-1603
3-153
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604310 Chute(For Head exchange) teaching Height
Flange of Nozzle is not detected within the predetermine range.(E/NR)
Please remeasure the height teach after teaching the head rotation on the angle
axis.
604311 Chute(For Head exchange) teaching Height
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
604312 Chute(For Head exchange) teaching Height
Program Error
-----
604313 Chute(For Head exchange) teaching Height
Offset is 1mm less than the set value.
-----
604314 Chute(For Head exchange) teaching Height
Offset is 1mm more than the set value.
-----
604315 Chute(For Head exchange) teaching Height
The value of Flowmeter is higher than 5.0V.
-----
604316 Chute(For Head exchange) teaching Height
The value of Flowmeter is lower than 4.7V.
-----
604317 Chute(For Head exchange) teaching Height
ThereisnomeasureddataofNoz1.ItisnecessarytomeasureNoz1rst.
-----
604318 Chute(For Head exchange) teaching Height
CannotmeasureitforXY-coordisnotdened.
-----
604319 Chute(For Head exchange) teaching Height
Error in Flowing Quantity
-----
604401 Teaching Height of Stocker Master
Error is detected before starting Detection on Linear Measure Sensor.(There is a
possibility that Linear measure sensor is broken, or Odd Noz is placed.)
-----
604402 Teaching Height of Stocker Master
Time-out of [OFF] signal of Linear measure sensor
-----
604403 Teaching Height of Stocker Master
Error in DD-axis
-----
604404 Teaching Height of Stocker Master
Error in NS-axis
-----
604405 Teaching Height of Stocker Master
Error in DD/NS-axis
-----
1109-006

4OM-1603
3-154
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604406 Teaching Height of Stocker Master
Time-out of DD/NS-axis
-----
604407 Teaching Height of Stocker Master
Error in calculating drive wave of HL-axis
-----
604408 Teaching Height of Stocker Master
Error in calculating drive wave of NL-axis
-----
604409 Teaching Height of Stocker Master
Time-out of starting HL/NL-axis movement
-----
60440a Teaching Height of Stocker Master
Time-out of starting HL-axis movement
-----
60440b Teaching Height of Stocker Master
Time-out of starting NL-axis movement
-----
60440c Teaching Height of Stocker Master
Time-outofnishingHL/NL-axismovement
-----
60440d Teaching Height of Stocker Master
Failed in measuring real time of linear measure sensor.
-----
60440e Teaching Height of Stocker Master
Error in measuring Linear measure sensor
-----
60440f Teaching Height of Stocker Master
Flange of Nozzle is not detected within the predetermine range.(Not E/NR)
Please remeasure the height teach after teaching the head rotation on the angle
axis.
604410 Teaching Height of Stocker Master
Flange of Nozzle is not detected within the predetermine range.(E/NR)
Please remeasure the height teach after teaching the head rotation on the angle
axis.
604411 Teaching Height of Stocker Master
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
604412 Teaching Height of Stocker Master
Program Error
-----
604413 Teaching Height of Stocker Master
Offset is 1mm less than the set value.
-----
604414 Teaching Height of Stocker Master
Offset is 1mm more than the set value.
-----
1109-006

4OM-1603
3-155
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604415 Teaching Height of Stocker Master
The value of Flowmeter is higher than 5.0V.
-----
604416 Teaching Height of Stocker Master
The value of Flowmeter is lower than 4.7V.
-----
604417 Teaching Height of Stocker Master
ThereisnomeasureddataofNoz1.ItisnecessarytomeasureNoz1rst.
-----
604418 Teaching Height of Stocker Master
CannotmeasureitforXY-coordisnotdened.
-----
604419 Teaching Height of Stocker Master
Error in Flowing Quantity
-----
604501 Teaching Pickup-Height
Error is detected before starting Detection on Linear Measure Sensor. (There is a
possibility that Linear measure sensor is broken, or Odd Noz is placed.)
-----
604502 Teaching Pickup-Height
Time-out of [OFF] signal of Linear measure sensor
-----
604503 Teaching Pickup-Height
Error in DD-axis
-----
604504 Teaching Pickup-Height
Error in NS-axis
-----
604505 Teaching Pickup-Height
Error in DD/NS-axis
-----
604506 Teaching Pickup-Height
Time-out of DD/NS-axis
-----
604507 Teaching Pickup-Height
Error in calculating drive wave of HL-axis
-----
604508 Teaching Pickup-Height
Error in calculating drive wave of NL-axis
-----
604509 Teaching Pickup-Height
Time-out of starting HL/NL-axis movement
-----
60450a Teaching Pickup-Height
Time-out of starting HL-axis movement
-----
1109-006