4OM-1603-007_w.pdf - 第304页

4OM-1603 3-129 3. Error IDs and Remedial Procedures : Chap.3 Error ID Error Name, Description, Cause, and Remedy 51 1209 T ransfer Section's Preparation Error Downward movement on PCB Stopper(AL) is abnormal. There …

100%1 / 379
4OM-1603
3-128
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
511004 Head1 Preparation Error
There is a possibility that Nozzle is falling while processing the preparation.
PleaseconrmtheplacedNozzleonHead.
-----
511101 Head2 Preparation Error
Because abnormality had occurred while processing the preparation, processing
was interrupted.
-----
511102 Head2 Preparation Error
Because abnormality had occurred while processing the preparation, processing
was interrupted.
-----
511103 Head2 Preparation Error
Because abnormality had occurred while processing the preparation, processing
was interrupted.
-----
511104 Head2 Preparation Error
There is a possibility that Nozzle is falling while processing the preparation.
PleaseconrmtheplacedNozzleonHead.
-----
511201 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(L) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511202 Transfer Section's Preparation Error
Upward movement on PCB Stopper(L) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511203 Transfer Section's Preparation Error
Downward movement on PCB Stopper(L) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511204 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(R) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511205 Transfer Section's Preparation Error
Upward movement on PCB Stopper(R) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511206 Transfer Section's Preparation Error
Downward movement on PCB Stopper(R) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511207 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(AL) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511208 Transfer Section's Preparation Error
Upward movement on PCB Stopper(AL) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
1109-006
4OM-1603
3-129
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
511209 Transfer Section's Preparation Error
Downward movement on PCB Stopper(AL) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511210 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(AR) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511211 Transfer Section's Preparation Error
Upward movement on PCB Stopper(AR) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511212 Transfer Section's Preparation Error
Downward movement on PCB Stopper(AR) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511213 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(BL) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511214 Transfer Section's Preparation Error
Upward movement on PCB Stopper(BL) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511215 Transfer Section's Preparation Error
Downward movement on PCB Stopper(BL) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511216 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(BR) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511217 Transfer Section's Preparation Error
Upward movement on PCB Stopper(BR) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511218 Transfer Section's Preparation Error
Downward movement on PCB Stopper(BR) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511219 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(REV) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511220 Transfer Section's Preparation Error
Upward movement on PCB Stopper(REV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511221 Transfer Section's Preparation Error
Downward movement on PCB Stopper(REV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511222 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(AREV) are detected
simultaneously.
Please check out the wiring and adjust Limits.
1109-006
4OM-1603
3-130
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
511223 Transfer Section's Preparation Error
Upward movement on PCB Stopper(AREV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511224 Transfer Section's Preparation Error
Downward movement on PCB Stopper(AREV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511225 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(BREV) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511226 Transfer Section's Preparation Error
Upward movement on PCB Stopper(BREV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511227 Transfer Section's Preparation Error
Downward movement on PCB Stopper(BREV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511301 Added squeeze error
Added squeeze is not completed.
Open the safety cover and check the placed components. Then, please remove
or revise them.
511401 Automatic correction of missed standard mark
Error in automatic correction of missed standard mark.
Please redo offset teaching of PCB mark position.
511402 Automatic correction of missed standard mark
Timeout of automatic correction of missed standard mark.
Please redo offset teaching of PCB mark position.
511403 Automatic correction of missed standard mark
Error in recognizing standard mark.
Please redo offset teaching of PCB mark position.
T4C14
1109-001