4OM-1603-007_w.pdf - 第305页
4OM-1603 3-130 3. Error IDs and Remedial Procedures : Chap.3 Error ID Error Name, Description, Cause, and Remedy 51 1223 T ransfer Section's Preparation Error Upward movement on PCB Stopper(AREV) is abnormal. There …

4OM-1603
3-129
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
511209 Transfer Section's Preparation Error
Downward movement on PCB Stopper(AL) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511210 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(AR) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511211 Transfer Section's Preparation Error
Upward movement on PCB Stopper(AR) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511212 Transfer Section's Preparation Error
Downward movement on PCB Stopper(AR) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511213 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(BL) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511214 Transfer Section's Preparation Error
Upward movement on PCB Stopper(BL) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511215 Transfer Section's Preparation Error
Downward movement on PCB Stopper(BL) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511216 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(BR) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511217 Transfer Section's Preparation Error
Upward movement on PCB Stopper(BR) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511218 Transfer Section's Preparation Error
Downward movement on PCB Stopper(BR) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511219 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(REV) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511220 Transfer Section's Preparation Error
Upward movement on PCB Stopper(REV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511221 Transfer Section's Preparation Error
Downward movement on PCB Stopper(REV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511222 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(AREV) are detected
simultaneously.
Please check out the wiring and adjust Limits.
1109-006

4OM-1603
3-130
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
511223 Transfer Section's Preparation Error
Upward movement on PCB Stopper(AREV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511224 Transfer Section's Preparation Error
Downward movement on PCB Stopper(AREV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511225 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(BREV) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511226 Transfer Section's Preparation Error
Upward movement on PCB Stopper(BREV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511227 Transfer Section's Preparation Error
Downward movement on PCB Stopper(BREV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511301 Added squeeze error
Added squeeze is not completed.
Open the safety cover and check the placed components. Then, please remove
or revise them.
511401 Automatic correction of missed standard mark
Error in automatic correction of missed standard mark.
Please redo offset teaching of PCB mark position.
511402 Automatic correction of missed standard mark
Timeout of automatic correction of missed standard mark.
Please redo offset teaching of PCB mark position.
511403 Automatic correction of missed standard mark
Error in recognizing standard mark.
Please redo offset teaching of PCB mark position.
T4C14
1109-001

4OM-1603
3-131
3. Error IDs and Remedial Procedures : Chap.3
1109-006
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600101 P.C.B. recog camera & beam offset teach.
-----
-----
600102 P.C.B. recog camera & beam offset teach.
Error of Recognition Command response.
-----
600103 P.C.B. recog camera & beam offset teach.
Error of coordinates calculation.
-----
600104 P.C.B. recog camera & beam offset teach.
Error of Data set for XY Beam.
-----
600105 P.C.B. recog camera & beam offset teach.
Error of moving for XY Beam.
-----
600106 P.C.B. recog camera & beam offset teach.
Time-out in XY Beam
-----
600107 P.C.B. recog camera & beam offset teach.
Time-out of communication with recognition.
-----
600108 P.C.B. recog camera & beam offset teach.
Recognition failure of checker mark on parts recognition camera.
-----
600109 P.C.B. recog camera & beam offset teach.
Recognition failure of checker on reference pin.
-----
60010a P.C.B. recog camera & beam offset teach.
Recognition failure of checker mark on glass jig.
-----
600201 Comp. Recog. Camera offset teach.
Could not recognize the glass Jig.
PleaseconrmthatGlassJigissetonGlassJigplace.(Checkitbecausethereis
a possibility that nozzle is not on head, or vacuum is not "ON".)
600202 Comp. Recog. Camera offset teach.
The result of Teaching is out of permission values.
PleaseconrmwhetherGlassJigispicked-upcorrectlyornot.Pleaseadjustit
with Teach Plate Offset if not.
600203 Comp. Recog. Camera offset teach.
Error of Recognition command response.
-----
600204 Comp. Recog. Camera offset teach.
Error of coordinates calculation.
-----