4OM-1603-007_w.pdf - 第324页
4OM-1603 3-149 3. Error IDs and Remedial Procedures : Chap.3 Error ID Error Name, Description, Cause, and Remedy 604106 T eaching Placement-Height T ime-out of DD/NS-axis ----- 604107 T eaching Placement-Height Error in …

4OM-1603
3-148
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
602903 Teaching PCB height measured Sensor
Time-out of Communication with Recog.
-----
602904 Teaching PCB height measured Sensor
Could not measure Sensor position Offset correctly.
Please retry to adjust PCB height measured Sensor.
602905 Teaching PCB height measured Sensor
Error of measuring PCB height Sensor
-----
602906 Teaching PCB height measured Sensor
Time-out of measuring PCB height Sensor.
-----
602907 Teaching PCB height measured Sensor
The result of PCB height measured Sensor is out of Permission values.
Please retry to adjust PCB height measured Sensor.
602908 Teaching PCB height measured Sensor
Error of processing in Zero Shift of PCB height measured Sensor.
-----
603001 XY Origin teach
Failed to recognize Origin Correction Mark
Modify the teaching position and execute teaching again.
604001 Automatic Teaching on producing operation.
Failed to recognize a nozzle in Head rotation center offset teaching.
-----
604002 Automatic Teaching on producing operation.
Error in recognition command response in Head rotation center offset teaching.
-----
604003 Automatic Teaching on producing operation.
Could not recognize the Standard Mark.
-----
604101 Teaching Placement-Height
Error is detected before starting Detection on the Linear Sensor.(There is a
possibility that the Linear measure Sensor is broken , or Odd Noz is placed)
-----
604102 Teaching Placement-Height
Time-out of [OFF] signal of Linear measure sensor
-----
604103 Teaching Placement-Height
Error in DD-axis
-----
604104 Teaching Placement-Height
Error in NS-axis
-----
604105 Teaching Placement-Height
Error in DD/NS-axis
-----
1109-006

4OM-1603
3-149
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604106 Teaching Placement-Height
Time-out of DD/NS-axis
-----
604107 Teaching Placement-Height
Error in calculating drive wave of HL-axis
-----
604108 Teaching Placement-Height
Error in calculating drive wave of NL-axis
-----
604109 Teaching Placement-Height
Time-out of starting HL/NL-axis movement
-----
60410a Teaching Placement-Height
Time-out of starting HL-axis movement
-----
60410b Teaching Placement-Height
Time-out of starting NL-axis movement
-----
60410c Teaching Placement-Height
Time-outofnishingHL/NL-axismovement
-----
60410d Teaching Placement-Height
Failed in measuring real time of linear measure sensor.
-----
60410e Teaching Placement-Height
ODD Noz is placed on Head, or error is detected during linear measure sensor.
-----
60410f Teaching Placement-Height
Flange of Nozzle is not detected within the predetermine range.(Not E/NR)
Please remeasure the height teach after teaching the head rotation on the angle
axis.
604110 Teaching Placement-Height
Flange of Nozzle is not detected within the predetermine range.(E/NR)
Please remeasure the height teach after teaching the head rotation on the angle
axis.
604111 Teaching Placement-Height
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
604112 Teaching Placement-Height
Program Error
-----
604113 Teaching Placement-Height
Offset is 1mm less than the set value.
-----
604114 Teaching Placement-Height
Offset is 1mm more than the set value.
-----
1109-006

4OM-1603
3-150
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604115 Teaching Placement-Height
The value of Flowmeter is higher than 5.0V.
-----
604116 Teaching Placement-Height
The value of Flowmeter is lower than 4.7V.
-----
604117 Teaching Placement-Height
ThereisnomeasureddataofNoz1.ItisnecessarytomeasureNoz1rst.
-----
604118 Teaching Placement-Height
CannotmeasureitforXY-coordisnotdened.
-----
604119 Teaching Placement-Height
Error in Flowing Quantity
-----
604201 Chute(For adjustment when shipping up) Teaching Height
Error is detected before starting Detection on Linear Measure Sensor.(There is a
possibility that Linear measure sensor is broken, or Odd Noz is placed.)
-----
604202 Chute(For adjustment when shipping up) Teaching Height
Time-out of [OFF] signal of Linear measure sensor
-----
604203 Chute(For adjustment when shipping up) Teaching Height
Error in DD-axis
-----
604204 Chute(For adjustment when shipping up) Teaching Height
Error in NS-axis
-----
604205 Chute(For adjustment when shipping up) Teaching Height
Error in DD/NS-axis
-----
604206 Chute(For adjustment when shipping up) Teaching Height
Time-out of DD/NS-axis
-----
604207 Chute(For adjustment when shipping up) Teaching Height
Error in calculating drive wave of HL-axis
-----
604208 Chute(For adjustment when shipping up) Teaching Height
Error in calculating drive wave of NL-axis
-----
604209 Chute(For adjustment when shipping up) Teaching Height
Time-out of starting HL/NL-axis movement
-----
60420a Chute(For adjustment when shipping up) Teaching Height
Time-out of starting HL-axis movement
-----
1109-006