4OM-1603-007_w.pdf - 第336页

4OM-1603 3-161 3. Error IDs and Remedial Procedures : Chap.3 1012-005 3.14 T est Error ID Error Name, Description, Cause, and Remedy 610101 Opearation error has occurred. ----- ----- T4C16

100%1 / 379
4OM-1603
3-160
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604715 Teaching Height of Traverse Chute
The value of Flowmeter is higher than 5.0V.
------
604716 Teaching Height of Traverse Chute
The value of Flowmeter is lower than 4.7V.
------
604717 Teaching Height of Traverse Chute
ThereisnomeasureddataofNoz1.ItisnecessarytomeasureNoz1rst.
------
604718 Teaching Height of Traverse Chute
CannotmeasureitforXY-coordisnotdened.
------
604719 Teaching Height of Traverse Chute
Error in Flowing Quantity
------
T4C15
1109-006
4OM-1603
3-161
3. Error IDs and Remedial Procedures : Chap.3
1012-005
3.14 Test
Error ID Error Name, Description, Cause, and Remedy
610101 Opearation error has occurred.
-----
-----
T4C16
4OM-1603
3-162
3. Error IDs and Remedial Procedures : Chap.3
1012-005
3.15 Coplanarity
Error ID Error Name, Description, Cause, and Remedy
6b0101 Coplanarity System Error
Communication time-out.
Check the coupling network cable between the Coplanarity unit PC and the main
machine.
6b0102 Coplanarity System Error
Error command.
There is a possibility of following error.
1. Coplanarity Unit
2. Software Error
Shut down the device, and turn it on again. Please contact the service when not
repaired even if turns it on again.
6b0103 Coplanarity System Error
Error received data.
There is a possibility of following error.
1. Coplanarity Unit
2. Software Error
Shut down the device, and turn it on again. Please contact the service when not
repaired even if turns it on again.
6b0104 Coplanarity System Error
Error sequence.
There is a possibility of following error.
1. Coplanarity Unit
2. Software Error
Shut down the device, and turn it on again. Please contact the service when not
repaired even if turns it on again.
6b1001 Coplanarity System Error
System error. (1000)
Error in Coplanarity Unit. Shut down the device, and turn it on again. Please
contact the service when not repaired even if turns it on again.
6b1011 Coplanarity System Error
Memory error in unit.(1010)
Error in Coplanarity Unit. Shut down the device, and turn it on again. Please
contact the service when not repaired even if turns it on again.
6b1061 Coplanarity System Error
Laser error.(1060)
Error in Coplanarity Unit. Shut down the device, and turn it on again. Please
contact the service when not repaired even if turns it on again.
6b1071 Coplanarity System Error
Memory error in sensor section. (1070)
Error in Coplanarity Unit. Shut down the device, and turn it on again. Please
contact the service when not repaired even if turns it on again.
6b1081 Coplanarity System Error
Sensor cable not connected. (1080)
Check the connection between the Coplanarity unit PC and the sensor head.