4OM-1603-007_w.pdf - 第285页
4OM-1603 3-1 10 3. Error IDs and Remedial Procedures : Chap.3 1 109-006 Error ID Error Name, Description, Cause, and Remedy 4b0c01 NozzleConrmationErrorbeforepickupcomp(Detect AfterPlacement) Because a componen…

4OM-1603
3-109
3. Error IDs and Remedial Procedures : Chap.3
1109-006
Error ID Error Name, Description, Cause, and Remedy
4b0702 Connection Error.
Failed in communications with the Recog. CPU.
-----
4b0801 Linear measure operation is abnormal.
Linear measure was found abnormality while measuring.
ThereisapossibilityofLightEmitterandReceiverbroken.PleaseconrmError
from Log Request Screen(Unit adjustment -> Linear measure Sensor Screen)
4b0802 Linear measure operation error
The measurement by the linear measure sensor was not completed on time.
Communication connector of Linear measure Sensor P.C.B is taken off. Please
conrmwhethertheitemsofLS-RLS-S(DeviceCheck->List)isYellow.HLS
communication cable could not be connected and such like things.
4b0803 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
LightEmitterandReceivercouldhaveawandsoil.Pleasecleanitup.Please
press [Operation] on the screen(Unit adjustment -> Linear measure Sensor ->
DetectiontestScreen)andconrmwhetherthereisanerror
4b0804 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
There is a possibility of Line Sensor P.C.B. broken
4b0805 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
A small light quantity of Light Emitter. Please exchange Light Emitter.
4b0806 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
There is a possibility of Line Sensor P.C.B. broken. Either, Please update Version
on the screen(Unit adjustment -> Linear measure Sensor -> Correct data read
Screen)
4b0807 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
PleaseconrmErrorfromLogRequestScreen(Unitadjustment->Linear
measureSensorScreen).Either,pleaseconrmwhethertheitemsofLS-RLS-
S(Device Check -> List) is Yellow.
HLS communication cable could not be connected and such like things.
4b0808 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
PleaseconrmErrorfromLogRequestScreen(Unitadjustment->Linear
measureSensorScreen).Either,pleaseconrmwhethertheitemsofLS-RLS-
S(Device Check -> List) is Yellow.
HLS communication cable could not be connected and such like things.
4b0809 Linear measure operation error
There is a problem in the linear measure Sensor.(Strobe Signal did not turn off
within predetermined time.)
PleaseconrmErrorfromLogRequestScreen(Unitadjustment->Linear
measureSensorScreen).Either,pleaseconrmwhethertheitemsofLS-RLS-
S(Device Check -> List) is Yellow.
HLS communication cable could not be connected and such like things.

4OM-1603
3-110
3. Error IDs and Remedial Procedures : Chap.3
1109-006
Error ID Error Name, Description, Cause, and Remedy
4b0c01 NozzleConrmationErrorbeforepickupcomp(DetectAfterPlacement)
Because a component was found on a nozzle, it stopped after disposal.
The result could have some problems.
Please check placement state on placement step recovery screen.
4b0c02 NozzleConrmationErrorbeforepickupcomp
The remains component was found on a nozzle during production.
PleaseconrmwhetherthereisanerrorintheP.C.B.
4b0c03 NozzleConrmationErrorbeforepickupcomp(DetectAfterDiscard)
Because a component was found on a nozzle, it stopped after disposal.
Pleaseconrmandcleanupthenozzleifthiserrorcontinues.
4b0e01 Splicing tape set error
The joint part of splicing tape is not correctly set. Please extract a feeder and
check whether the tape has separated from the guide.
-----
4b1201 Press in error / Insertion error
There is an error with the component pressed in or Insertion
OpensafetycoverandconrmthecomponentonP.C.B.Pleaseremoveitor
revise it
4b19ff Zeroing of single axis error
Timeout in zeroing of single axis.
-----
4b2001 P.C.B Height Measurement
Abnormal measured value was detected.
Check the measurement position.
4b2002 P.C.B Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2003 P.C.B Height Measurement
The abnormality number of times of measured value was beyond a set point.
Running is stopped.
-----
4b2004 P.C.B Height Measurement
The abnormality number of times of measured value was beyond a set point.
-----
4b2005 P.C.B Height Measurement
A measurement result is abnormal(measure in arbitrary position)
Check the measurement position.
4b2006 P.C.B Height Measurement
Surpass a measurement range. (+ direction)
-----
4b2007 P.C.B Height Measurement
Surpass a measurement range. (- direction)
-----
4b2008 P.C.B Height Measurement
Detected a curve more than permission values. (+ direction)
-----

4OM-1603
3-111
3. Error IDs and Remedial Procedures : Chap.3
1109-006
Error ID Error Name, Description, Cause, and Remedy
4b2009 P.C.B Height Measurement
Detected a curve more than permission values. (- direction)
-----
4b200a P.C.B Height Measurement
Error of the result measured by a master jig (height)
Check if the master jig (height) has some dirt and foreign particles.
4b200b P.C.B Height Measurement
Failed in wearing height revision.
-----
4b200c P.C.B Height Measurement
An abnormal measurement was detected by the multipoint measurement.
Check the measurement position.
4b200d P.C.B Height Measurement
Recovery by the multipoint measurement failed because the measurement result
wasinsufcient.
Check the measurement position.
4b2011 P.C.B Height Measurement
Measurement time-out
-----
4b2081 P.C.B Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2082 P.C.B Height Measurement
Failed in wearing height revision.
-----
4b2083 P.C.B Height Measurement
Measurement time-out
-----
4b2084 P.C.B Height Measurement
The coordinate where the height measurement was impossible was appointed.
Please appoint a coordinate in a measurable range.
4b2101 SSC network abnormal
There is abnormal in SSC network.
PleaseconrmthecableofSSCnetwork.
4b2102 SSC network abnormal
ThereisaprobleminconnectiontoServoAmplier(XY).
(1) Shut down the machine and check the connection between the position board
andamplier.
(2)Checkwhetherornottheservoampliersaredamaged.
4b2103 SSC network abnormal
ThereisaprobleminconnectiontoServoAmplier(Head).
(1) Shut down the machine and check the connection between the position board
andamplier.
(2)Checkwhetherornottheservoampliersaredamaged.