4OM-1603-007_w.pdf - 第290页
4OM-1603 3-1 15 3. Error IDs and Remedial Procedures : Chap.3 Error ID Error Name, Description, Cause, and Remedy 4b02803 PCB-ID communication Error . A problem was found in the unit PCB ID information. Delete the P .C.B…

4OM-1603
3-114
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
4b2411 Feeder (Movement Error)
Alarm Code:E5 - Redundant Order Error (A feeding error may occur.)
Conrmwhetherornotthetapeisbeingjammedonthepath.
Conrmthereeltooperatesmoothly.
Conrmwhetherornotsomecomponentsanddustarebeingcaughtinthe
sprocket.
Conrmwhetherornotsomecomponentsanddustarebeingcaughtinthetape
feeding gear.
4b2412 Feeder (Movement Error)
ErrorinconrmingconnectionofFeeder
Please check connection of Feeder
4b2413 Feeder (Movement Error)
Cannot send Tape because alarm is found in one side Lane of Dual Feeder.
Please execute recovery process, and then operate it again.
4b24a3 Feeder (Movement Error)
Feeder error (feeding time-out)
-----
4b2501 Splicing Operation failed
Alarm Code:E3 - (1)No supplied history/ (2)Dirty splicing detection sensor (dust
adhesion)
(1) Please operate to resupply components in the machine after splicing
operation.
(2) Please clean the joint detection sensor.
4b2601 Unit P.C.B. B.B.R. Information
There is no information in the relevant P.C.B. (on the Transfer Conveyor).
Delete the BBR information after removing the P.C.B..
4b2602 Unit P.C.B. B.B.R. Information
There is no information in the relevant P.C.B. (on the Transfer XY-Table).
Delete the BBR information after removing the P.C.B..
4b2603 Unit P.C.B. B.B.R. Information
A problem was found in the unit PCB BBR information.
Delete the BBR information after removing the P.C.B..
4b2701 Start Process(Feeder Connection Error)
Aspecialfeederisappointed.Pleaseconrmthemodelofasetfeeder.
-----
4b2711 Start Process(Feeder Connection Error)
ACVCheckError.ComponentIDonthefeederisnotsameasonespeciedby
current program.
-----
4b2713 Start Process(Feeder Connection Error)
There is a splicing failure feeder.
-----
4b2722 Start Process(Feeder Connection Error)
Feeder is not ready
-----
1109-006

4OM-1603
3-115
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
4b02803 PCB-ID communication Error.
A problem was found in the unit PCB ID information.
Delete the P.C.B.-ID information after removing the P.C.B.
4b2c01 Error in connection between CPU
Failed in communications with the Control CPU.
-----
4b2c02 Error in connection between CPU
Failed in communications with the Recog. CPU.
-----
4b3001 Cutter Error
Program Error(There is a operation mode which is not set)
-----
4b3002 Cutter Error
There is a problem in Cutter-axis. (Zeroing operation)
-----
4b3003 Cutter Error
There is a time-out in Cutter-axis.(Zeroing operation start)
-----
4b3004 Cutter Error
Cutter-axis Time-out(Zeroing)
-----
4b3005 Cutter Error
Zeroing of Cutter-axis is not completed.
-----
4b3006 Cutter Error
There is a problem in Cutter-axis. (Positioning Operation)
-----
4b3007 Cutter Error
Cutter-axis Time-out(Positioning Operation)
-----
4b3008 Cutter Error
Alarm of Cutter-axis was detected.
-----
4b3009 Cutter Error
Recede operation was executed because alarm was detected during positioning
operation of Cutter-axis.
Pleaseconrmwhetherthereisanerrorincutterunit(Beingjammedincutter
layer)
4b300a Cutter Error
Can not communicate with SV-NET P.C.B.
PleaseconrmAE-LINKwiringandPowerwiring.
4b300b Cutter Error
Can not communicate with Driver
PleaseconrmPowerwiringandAE-LINKwiringofdriverinCutterunit.
4b300c Cutter Error
Time-out of waiting for initializing completely
PleaseconrmAE-LINKwiringandPowerwiring.
1109-006

4OM-1603
3-116
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
4b300d Cutter Error
Test mode of cutter is valid.
Please clear the check of [Cutter Movement disable] in the screen of test mode.
4b300e Cutter Error
The set of operation mode of Cutter is "Disable".
Please set operating mode of Cutter "Enable".
4b300f Cutter Error
Cutter can not move because Feeder Base is in downward position.
Please press READY switch of Feeder Base and move Feeder base to input
position.
4b3010 Cutter Error
Cutter can not move because Feeder Base in not positioned correctly.
Please connect connector of Feeder base.
4b3011 Cutter Error
Failed in reading the number of connection axes.
PleaseconrmAE-LINKwiringandPowerwiring.
4b3012 Cutter Error
Communication status Error
PleaseconrmAE-LINKwiringandPowerwiring.
4b3013 Cutter Error
Communication status Error(Stand by)
PleaseconrmAE-LINKwiringandPowerwiring.
4b3014 Cutter Error
Communication Status Error(Alarm)
PleaseconrmthewiringofdriverinFeederBaseunit
4b3015 Cutter Error
Communication Status Error(OT)
PleaseconrmthewiringofOriginSensor.
4b3016 Cutter Error
Communication Status Error(Connection O)
PleaseconrmAE-LINKwiringandPowerwiring.
4b3017 Cutter Error
Communication Status Error(Driver Alarm)
PleaseconrmthewiringofdriverinFeederBaseunit
4b3018 Cutter Error
Communication Status Error(SV-NET stopping)
PleaseconrmAE-LINKwiringandPowerwiring.
4b3019 Cutter Error
Communication Status Error(Out of Connection number)
PleaseconrmAE-LINKwiringandPowerwiring.
4b301a Cutter Error
Communication Status Error(SV-NET Error)
PleaseconrmAE-LINKwiringandPowerwiring.
4b301b Cutter Error
Cutter-axis is not connected.
PleaseconrmAE-LINKwiringandPowerwiring.
1109-006