4OM-1603-007_w.pdf - 第255页
4OM-1603 3-80 3. Error IDs and Remedial Procedures : Chap.3 1012-005 Error ID Error Name, Description, Cause, and Remedy 49070d Nozzle set up It failed in the nozzle placement check. Conrmtherecognitionimageandsele…

4OM-1603
3-79
3. Error IDs and Remedial Procedures : Chap.3
1012-005
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
490603 Conveyor Width Automatic Adjustment
PCB exists on the L conveyor.
-----
490604 Conveyor Width Automatic Adjustment
PCB exists on the R conveyor.
-----
490617 Conveyor Width Automatic Adjustment
Software limit
-----
490690 Conveyor Width Automatic Adjustment
Auto Setup Error(Others).
-----
490701 Nozzle set up
Nozzle Stocker is not set.
Please check whether it is correctly set to the stocker base.
490702 Nozzle set up
Motor Error Detection.
-----
490703 Nozzle set up
Nozzle Stocker Shutter open/close failed.
Thereisnooatgoingupofanozzle,orpleasecheckwhetherthereisany
connection etc. in opening and closing.
490704 Nozzle set up
The up/down movement of Nozzle Stocker failed.
PleaseconrmwhetherUpper/LowerCylinderhasnoerror.
490705 Nozzle set up
Nozzle placing was not found in the stocker.
Check whether there is any difference in stocker arrangement data and real
arrangement.
490707 Nozzle set up
Thereisnofreespacefornozzlestoring.Pleaseconrmthearrangementdata.
PleaseconrmtheStockerarrangementdata.
490708 Nozzle set up
There are neither a free space nor a nozzle for nozzle exchange.
PleasesetupaninsufcientnozzleinNozzlestocker.
490709 Nozzle set up
Nozzle exchange abnormal data was found.
PleaseconrmthenozzlearrangementandtheStockerarrangementdata.
49070a Nozzle set up
Nozzle stocker position teaching failed.
Please teach the Nozzle stocker position again on the instruction screen.
49070c Nozzle set up
Nozzle level teach error Detection.
Please execute the nozzle level teaching again on the nozzle level teach screen,
andconrmthereisnounexpectedvalue.

4OM-1603
3-80
3. Error IDs and Remedial Procedures : Chap.3
1012-005
Error ID Error Name, Description, Cause, and Remedy
49070d Nozzle set up
It failed in the nozzle placement check.
Conrmtherecognitionimageandselectthenozzleexistence.
Please select a recognition image and choose the existence of a nozzle.
49070e Nozzle set up
The remains nozzle was detected on the head. The nozzle cannot be set to this
position.
Pleaseconrmthenozzlehasnotadheredtotheposition.
Moreover, please clean the linear measure when not adhering.
49070f Nozzle set up
Abnormal nozzle level detected. Possibilities are the nozzle was not fully inserted
in the head, or linear measure saw dust or scratch.
Pleaseconrmwhetherthenozzlehasadheredtotheposition.
490710 Nozzle set up
The receipt nozzle was undetectable on the head.
Pleaseconrmwhetherthenozzlehasadheredtotheposition.
490711 Nozzle set up
The remains nozzle was detected on the head.
Pleaseconrmthenozzlehasnotadheredtotheposition.
Moreover, please clean the linear measure when not adhering.
490712 Nozzle set up
The linear measure error occurred in the head nozzle existence check.
Pleaseconrmthenozzlearrangement,andexecutethelevelteaching.
490713 Nozzle set up
The nozzle exchange sequence error occurred.
Pleaseconrmthenozzleplacement.
490716 Nozzle set up
Time-out of close nozzle stocker operation.
Nozzlestockerwasopenedforsafety.Pleaseconrmwhetherthereisnoriseto
the surface the nozzle is not in opening and shutting caught state.
490722 Nozzle set up
An error occurred with the nozzle existence check in the stocker before the nozzle
is stored.
-----
490723 Nozzle set up
It failed in the nozzle storage check.
Conrmtherecognitionimageandselectthenozzleexistence.
-----
490730 Nozzle set up
Error in calculating recognized position of Nozzle ID.(XY-axis)
-----
490731 Nozzle set up
Failed in starting XY-axis.
-----
490732 Nozzle set up
Time-out of XY-axis
-----

4OM-1603
3-81
3. Error IDs and Remedial Procedures : Chap.3
1012-005
Error ID Error Name, Description, Cause, and Remedy
490733 Nozzle set up
Motor Error of XY-axis
-----
490734 Nozzle set up
Error in Light on of P.C.B. recognition camera.
-----
490735 Nozzle set up
Error in capturing a image of P.C.B. recognition camera.
-----
490736 Nozzle set up
Error in recognizing Nozzle ID
-----
490737 Nozzle set up
Error in Light Off of P.C.B. recognition camera.
-----
490738 Nozzle set up
Error in calculating Nozzle check position internal stocker.(XY-axis)
-----
490739 Nozzle set up
Error in recognizing Nozzle existence.
-----
49073A Nozzle set up
Can not recognize Nozzle ID
PleaseconrmthedirectionofNozzleandtheexistenceofMarking,thedirt
inside Nozzle stocker.
49073B Nozzle set up
Nozzle set in Nozzle Stocker and Nozzle data is not Identical.
PleaseconrmNozzleandNozzledataofthemachineinsidenozzlestocker.
49073C Nozzle set up
Error in nozzle exchange
-----
49073D Nozzle set up
Error in recognition sequence of Nozzle ID.
49073E Nozzle set up
Necessary Stocker Area for recognition Nozzle ID is skipped.
Clear the skip set of nozzle stocker.
49073F Nozzle set up
Time-out of Nozzle type data received.
-----
490740 Nozzle set up
Error of Nozzle type data received.
-----
490741 Nozzle set up
Error in updating Nozzle data.
-----