4OM-1603-007_w.pdf - 第262页

4OM-1603 3-87 3. Error IDs and Remedial Procedures : Chap.3 Error ID Error Name, Description, Cause, and Remedy 49078C Nozzle set up Exchanging Noz has not started within predetermined time ----- 49078D Nozzle set up Exc…

100%1 / 379
4OM-1603
3-86
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
49077D Nozzle set up
RecognizingNozStockerMarkhasnotnishedwithinpredeterminedtime.
-----
49077E Nozzle set up
Error in recognizing Noz Stocker Mark
-----
49077F Nozzle set up
Error in recognization of the existence of Noz
-----
490780 Nozzle set up
RecognizationoftheexistenceofNozhasnotnishedwithinpredeterminedtime
-----
490781 Nozzle set up
Error in recognizing the existence of Noz
-----
490782 Nozzle set up
Error in recognizing Noz ID
-----
490783 Nozzle set up
RecognizingNozIDhasnotnishedwithinpredeterminedtime
-----
490784 Nozzle set up
Error in recognizing of Noz ID
-----
490785 Nozzle set up
Time-out of starting linear Measure detect
-----
490786 Nozzle set up
Time-out of reading out the result of Linear Measure detect
-----
490787 Nozzle set up
Error in the result of Linear Measure detect
-----
490788 Nozzle set up
Time-out of starting linear Measure detect (Noz diameter Recog)
-----
490789 Nozzle set up
Time-out of reading out the result of Linear Measure detect (Noz diameter Recog)
-----
49078A Nozzle set up
Error in the result of Linear Measure detect (Noz diameter Recog)
-----
49078B Nozzle set up
Failed in getting Noz type Data.
-----
1012-005
4OM-1603
3-87
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
49078C Nozzle set up
Exchanging Noz has not started within predetermined time
-----
49078D Nozzle set up
ExchangingNozhasnotnishedwithinpredeterminedtime
-----
49078E Nozzle set up
Error in setting Drive Wave of HL-axis
-----
49078F Nozzle set up
Error in setting Drive Wave of NL-axis
-----
490790 Nozzle set up
Error in setting Drive Wave of L-axis
-----
490791 Nozzle set up
Error in coordinate calculation of shifting the Origin
-----
490792 Nozzle set up
Error in setting Sequence Data of HL-axis
-----
490793 Nozzle set up
Error in HL-axis operating
-----
490794 Nozzle set up
Error in L-axis operating
-----
490795 Nozzle set up
Error in the nozzle stocker mark recog. There is a possibility that the stocker type
is wrong.
Pleaseconrmthatthesetstockerintheunitreplacescreenisthesameasthe
stocker type of the device. Please clean it up if there is no problem.
490796 Nozzle set up
It is impossible to place a nozzle whose end type is set besides [standard]
adjacent to a head.
-----
490797 Nozzle set up
It stopped by nozzle interference check.
Perform zeroing.
490798 Nozzle set up
Error in communication with recognition.
-----
490799 Nozzle set up
Time-out of communication with recognition.
-----
1109-006
4OM-1603
3-88
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
49079a Nozzle set up
Error in capturing a image with component recognizing camera.
-----
49079b Nozzle set up
To capture a image with component recognizing camera is not complete with the
predetermined time.
-----
49079c Nozzle set up
Error in recognition of nozzle position.
-----
49079d Nozzle set up
Time-out of recognition of nozzle position.
-----
49079e Nozzle set up
Failedinnozzlepositionteaching.PleaseconrmNozzleID,andthenreplacea
nozzle.
-----
49079f Nozzle set up
To set nozzle position data failed.
-----
4907A0 Nozzle set up
The nozzle stocker which is not for replace exists on input position.
Please perform all zeroing.
490801 Program -change linked operation
Program-changelinkedoperationhasnotnishedwithinappointedtime.
-----
496001 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W1-axis operating.
PleaseremovetheBackupPin\JigfromBackupBase.Or,conrmwhether
Sensor has error or not.
496002 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W2-axis operating.
PleaseremovetheBackupPin\JigfromBackupBase.Or,conrmwhether
Sensor has error or not.
496003 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W3-axis operating
PleaseremovetheBackupPin\JigfromBackupBase.Or,conrmwhether
Sensor has error or not.
496101 Conveyor Width W1 Error
Drive Alarm during Conveyor Width W1 axial operation.
ConrmresetMethodofdetailedSub-systemerrorcountsofAlarm.
1109-006