4OM-1603 3-139 3. Error IDs and Remedial Procedures : Chap.3 1 109-006 Error ID Error Name, Description, Cause, and Remedy 600903 T eaching Leaning Nozzle offset Error of coordinates calculation. ----- 600904 T eaching L…

4OM-1603
3-138
3. Error IDs and Remedial Procedures : Chap.3
1109-006
Error ID Error Name, Description, Cause, and Remedy
600707 Fly recog. Offset teach
Error of moving for XY Beam.
-----
600708 Fly recog. Offset teach
Time-out in XY Beam movement
-----
600709 Fly recog. Offset teach
Time-out of communication with recognition
-----
600801 Teaching Pick-up Position
Please push the Feeder Ready SW
-----
600802 Teaching Pick-up Position
Error of Feeder Mark Recognition
-----
600803 Teaching Pick-up Position
Feeder connection is set in test mode.
Please set test pattern "OK"
600804 Teaching Pick-up Position
The data of the feeder was not able to be read.
Please exchange Feeder
600805 Teaching Pick-up Position
Time-over of Feeder Mark Recognition Process
-----
600806 Teaching Pick-up Position
Time-out in XY Beam movement
-----
600807 Teaching Pick-up Position
Error of moving for XY Beam.
-----
600808 Teaching Pick-up Position
Error of processing Recognition Stop
-----
600809 Teaching Pick-up Position
Error of processing Light on
-----
60080a Teaching Pick-up Position
Error of processing image capture
-----
600901 Teaching Leaning Nozzle offset
Could not recognize Glass Jig
PleaseconrmthatGlassJigissetonGlassJigplace.(Checkitbecausethereis
a possibility that nozzle is not on head, or vacuum is not "ON".)
600902 Teaching Leaning Nozzle offset
Error of Recognition Command Response
-----

4OM-1603
3-139
3. Error IDs and Remedial Procedures : Chap.3
1109-006
Error ID Error Name, Description, Cause, and Remedy
600903 Teaching Leaning Nozzle offset
Error of coordinates calculation.
-----
600904 Teaching Leaning Nozzle offset
Error of Data set for XY Beam.
-----
600905 Teaching Leaning Nozzle offset
Error of moving for XY Beam.
-----
600906 Teaching Leaning Nozzle offset
Time-out in XY Beam movement
-----
600907 Teaching Leaning Nozzle offset
Time-out of communication with recognition.
-----
600908 Teaching Leaning Nozzle offset
Error of Leaning Nozzle offset teaching
-----
600909 Teaching Leaning Nozzle offset
Error of Noz Select Axis Pos. Offset Teaching
-----
60090A Teaching Leaning Nozzle offset
Noz Select Axis Pos. Offset is out of permission values.
There is a possibility that Head Rotate Theta Axis offset is not correct. / There is
apossibilitythatLightEmitterandReceiverofLinearmeasuringSensorhasaw
and soil / There is a possibility that Nozzle is damaged. / There is a possibility that
Head has some problem.
60090B Teaching Leaning Nozzle offset
Could not measure correctly on Noz Select Axis Pos. Offset Teaching.
There is a possibility that Head Rotate Theta Axis offset is not correct. / There is
apossibilitythatLightEmitterandReceiverofLinearmeasuringSensorhasaw
and soil / There is a possibility that Nozzle is damaged. / There is a possibility that
Head has some problem.
601001 Master nozzle level offset teach
Error is detected before Line Sensor measurement began
-----
601002 Master nozzle level offset teach
Error of NS-axis movement
-----
601003 Master nozzle level offset teach
Error of DD-axis movement
-----
601004 Master nozzle level offset teach
Time-out of NS-axis movement
-----

4OM-1603
3-140
3. Error IDs and Remedial Procedures : Chap.3
1109-006
Error ID Error Name, Description, Cause, and Remedy
601005 Master nozzle level offset teach
Time-out of DD-axis movement
-----
601006 Master nozzle level offset teach
Time-out when Line Sensor measurement began
-----
601007 Master nozzle level offset teach
Read Time-out of Line Sensor measurement
-----
601101 Noz level offset teaching
Time-out when Line Sensor measurement began
-----
601102 Noz level offset teaching
Read Time-out of Line Sensor measurement
-----
601103 Noz level offset teaching
Error during Line Sensor measurement
-----
601104 Noz level offset teaching
Error of dirty Line Sensor
-----
601105 Noz level offset teaching
Error of NS-axis Origin calculation
-----
601106 Noz level offset teaching
Error of NS-axis movement
-----
601107 Noz level offset teaching
Error of DD-axis Origin Calculation
-----
601108 Noz level offset teaching
Error of DD-axis movement
-----
601109 Noz level offset teaching
Program Error
-----
60110a Noz level offset teaching
Error before Line Sensor measurement began
-----
60110b Noz level offset teaching
Nozzle on Head is not placed
-----
601301 Noz stocker offset teaching
Error of coordinates calculation(XY)
-----