4OM-1603-007_w.pdf - 第326页

4OM-1603 3-151 3. Error IDs and Remedial Procedures : Chap.3 Error ID Error Name, Description, Cause, and Remedy 60420b Chute(For adjustment when shipping up) T eaching Height T ime-out of starting NL-axis movement -----…

100%1 / 379
4OM-1603
3-150
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604115 Teaching Placement-Height
The value of Flowmeter is higher than 5.0V.
-----
604116 Teaching Placement-Height
The value of Flowmeter is lower than 4.7V.
-----
604117 Teaching Placement-Height
ThereisnomeasureddataofNoz1.ItisnecessarytomeasureNoz1rst.
-----
604118 Teaching Placement-Height
CannotmeasureitforXY-coordisnotdened.
-----
604119 Teaching Placement-Height
Error in Flowing Quantity
-----
604201 Chute(For adjustment when shipping up) Teaching Height
Error is detected before starting Detection on Linear Measure Sensor.(There is a
possibility that Linear measure sensor is broken, or Odd Noz is placed.)
-----
604202 Chute(For adjustment when shipping up) Teaching Height
Time-out of [OFF] signal of Linear measure sensor
-----
604203 Chute(For adjustment when shipping up) Teaching Height
Error in DD-axis
-----
604204 Chute(For adjustment when shipping up) Teaching Height
Error in NS-axis
-----
604205 Chute(For adjustment when shipping up) Teaching Height
Error in DD/NS-axis
-----
604206 Chute(For adjustment when shipping up) Teaching Height
Time-out of DD/NS-axis
-----
604207 Chute(For adjustment when shipping up) Teaching Height
Error in calculating drive wave of HL-axis
-----
604208 Chute(For adjustment when shipping up) Teaching Height
Error in calculating drive wave of NL-axis
-----
604209 Chute(For adjustment when shipping up) Teaching Height
Time-out of starting HL/NL-axis movement
-----
60420a Chute(For adjustment when shipping up) Teaching Height
Time-out of starting HL-axis movement
-----
1109-006
4OM-1603
3-151
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
60420b Chute(For adjustment when shipping up) Teaching Height
Time-out of starting NL-axis movement
-----
60420c Chute(For adjustment when shipping up) Teaching Height
Time-outofnishingHL/NL-axismovement
-----
60420d Chute(For adjustment when shipping up) Teaching Height
Failed in measuring real time of linear measure sensor.
-----
60420e Chute(For adjustment when shipping up) Teaching Height
Error in measuring Linear measure sensor
-----
60420f Chute(For adjustment when shipping up) Teaching Height
Flange of Nozzle is not detected within the predetermine range.(Not E/NR)
Please remeasure the height teach after teaching the head rotation on the angle
axis.
604210 Chute(For adjustment when shipping up) Teaching Height
Flange of Nozzle is not detected within the predetermine range.(E/NR)
Please remeasure the height teach after teaching the head rotation on the angle
axis.
604211 Chute(For adjustment when shipping up) Teaching Height
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
604212 Chute(For adjustment when shipping up) Teaching Height
Program Error
-----
604213 Chute(For adjustment when shipping up) Teaching Height
Offset is 1mm less than the set value.
-----
604214 Chute(For adjustment when shipping up) Teaching Height
Offset is 1mm more than the set value.
-----
604215 Chute(For adjustment when shipping up) Teaching Height
The value of Flowmeter is higher than 5.0V.
-----
604216 Chute(For adjustment when shipping up) Teaching Height
The value of Flowmeter is lower than 4.7V.
-----
604217 Chute(For adjustment when shipping up) Teaching Height
ThereisnomeasureddataofNoz1.ItisnecessarytomeasureNoz1rst.
-----
604218 Chute(For adjustment when shipping up) Teaching Height
CannotmeasureitforXY-coordisnotdened.
-----
604219 Chute(For adjustment when shipping up) Teaching Height
Error in Flowing Quantity
-----
1109-006
4OM-1603
3-152
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604301 Chute(For Head exchange) teaching Height
Error is detected before starting Detection on Linear Measure Sensor.(There is a
possibility that Linear measure sensor is broken, or Odd Noz is placed.)
-----
604302 Chute(For Head exchange) teaching Height
Time-out of [OFF] signal of Linear measure sensor
-----
604303 Chute(For Head exchange) teaching Height
Error in DD-axis
-----
604304 Chute(For Head exchange) teaching Height
Error in NS-axis
-----
604305 Chute(For Head exchange) teaching Height
Error in DD/NS-axis
-----
604306 Chute(For Head exchange) teaching Height
Time-out of DD/NS-axis
-----
604307 Chute(For Head exchange) teaching Height
Error in calculating drive wave of HL-axis
-----
604308 Chute(For Head exchange) teaching Height
Error in calculating drive wave of NL-axis
-----
604309 Chute(For Head exchange) teaching Height
Time-out of starting HL/NL-axis movement
-----
60430a Chute(For Head exchange) teaching Height
Time-out of starting HL-axis movement
-----
60430b Chute(For Head exchange) teaching Height
Time-out of starting NL-axis movement
-----
60430c Chute(For Head exchange) teaching Height
Time-outofnishingHL/NL-axismovement
-----
60430d Chute(For Head exchange) teaching Height
Failed in measuring real time of linear measure sensor.
-----
60430e Chute(For Head exchange) teaching Height
Error in measuring Linear measure sensor
-----
60430f Chute(For Head exchange) teaching Height
Flange of Nozzle is not detected within the predetermine range.(Not E/NR)
Please remeasure the height teach after teaching the head rotation on the angle
axis.
1109-006