4OM-1603-007_w.pdf - 第147页
4OM-1603 2-16 2. Management Information : Chap.2 1 109-006 Management Information Code Display Area A (The outline of the Management Information) Display Area B (The details of the Management Information) 030502 Misident…

4OM-1603
2-15
2. Management Information : Chap.2
1109-006
Management
Information Code
Display Area A (The outline of the Management Information)
Display Area B (The details of the Management Information)
01900A Support Pin
"Vacuum/Blower" of Test Operation Mode is set "Disable".
Execute it after cancelling Test Operation Mode.
030162 Operation Requirement
The pattern cannot be switched
030413 Operation Requirement
Specify the order No.
030416 Operation Requirement
ACV server does not pass the authorization.
Please retry to connect to server on a screen [UNIT ADJ]-[ACV Set].
03041c Operation Requirement
ACVCheckError.ComponentIDonthefeederisnotsameasonespeciedby
current program.
030420 Operation Requirement
CommunicationswiththeACVserverisimpossible.AfterconrmingtheACV
server, please retry to perform it. [MAINT]-[UNIT ADJ]-[ACV ADJ].
030430 Operation Requirement
Can not detect Feeder cart(Block1).
Please set Feeder cart to the inside.[B0910, B0911]
030431 Operation Requirement
Can not detect Feeder cart(Block2).
Please set Feeder cart to the inside.[B0910, B0911]
030432 Operation Requirement
The connector of the feeder base (Block1) is not connected to the main body, so
that please connect it. [B0916]
030433 Operation Requirement
The connector of the feeder base (Block2) is not connected to the main body, so
that please connect it. [B0916]
030440 Operation Requirement
The Safety cover is open. Please close it.
030441 Operation Requirement
It is impossible to do Pass Operation without Cart because func of Traceability is
valid. Please restart after setting Option invalid.
030442 Operation Requirement
It cannot run because a simple Cover locked. First, set Stage ready OFF, then set
Stage ready ON.
030450 Operation Requirement
To run is impossible by start protect.
030451 Operation Requirement
Cannot start to run because the output folder on server is disconnected.
Please check output folder setting and the server status of output folder.
030501 Misidenticationatypeofmulti-tray
TheconnectedTrayunit(Block1)doesn'tmatchsettingsofDevice.Pleaseconrm
a type of tray unit, and set it on unit exchange screen.

4OM-1603
2-16
2. Management Information : Chap.2
1109-006
Management
Information Code
Display Area A (The outline of the Management Information)
Display Area B (The details of the Management Information)
030502 Misidenticationatypeofmulti-tray
TheconnectedTrayunit(Block2)doesn'tmatchsetupofDevice.Pleaseconrma
type of tray unit, and set it on Unit Exchange Screen.
030601 ConrmationofthepositionofNozStocker
Cannot use Noz stocker from the second to the forth line when full tray is used.
Please set the location of Noz stocker of Device (Block1) on Unit exchange
Screen.
030602 ConrmationofthepositionofNozStocker
Cannot use Noz stocker from the second to the forth line when full tray is used.
Please set the location of Noz stocker of Device (Block2) on Unit exchange
Screen.
030603 ConrmationofthepositionofNozStocker
Cannot use Noz stocker from the second to the forth line when full tray is used.
PleaseconrmthelocationofNozstockerofDevice(Block1).
030604 ConrmationofthepositionofNozStocker
Cannot use Noz stocker from the second to the forth line when full tray is used.
PleaseconrmthelocationofNozstockerofDevice(Block2).
030701 Conrmationof2DBarcodeData
MarkNo.ofOperatingParameter/2DBarCodedataisspeciedasAllSkip(0).
Please specify proper Mark No.
030801 Detect nozzle coming off multi-functional stocker
Machine (Block1) Detected that nozzle has come off the multi-functional stocker
of the 1st line.
030802 Detect nozzle coming off multi-functional stocker
Machine (Block1) Detected that nozzle has come off the multi-functional stocker
of the 4th line.
030803 Detect nozzle coming off multi-functional stocker
Machine (Block2) Detected that nozzle has come off the multi-functional stocker
of the 1st line.
030804 Detect nozzle coming off multi-functional stocker
Machine (Block2) Detected that nozzle has come off the multi-functional stocker
of the 4th line.
030901 Head nozzle dropped detect
Please lock the main safety cover. Please perform all-zeroing when the main
safety cover has already been locked.
050201 ConrmationofP.C.B.existence
Remove PCB from the conveyor. Please delete the PCB memory information on
the edit screen if it remains.
050202 ConrmationofP.C.B.existence
PCB is detected from Input position when Finish mode is set [Output].
Please PCB from conveyor.
050203 ConrmationofP.C.B.existence
PCB is detected from Output position when Finish mode is set [Input].
Please PCB from conveyor.
050204 ConrmationofP.C.B.existence
PCB is detected from Inlet sensor of input conveyor. Please remove PCB.

4OM-1603
2-17
2. Management Information : Chap.2
1109-006
Management
Information Code
Display Area A (The outline of the Management Information)
Display Area B (The details of the Management Information)
050205 ConrmationofP.C.B.existence
The operation mode of Lane A is set [STOP].
Please remove P.C.B. when not transferred.
050206 ConrmationofP.C.B.existence
The operation mode of Lane B is set [STOP].
Please remove P.C.B. when not transferred.
050207 ConrmationofP.C.B.existence
There is a possibility that there are 2 sheets of PCB on the input conveyor. Please
remove PCB from Deceleration Sensor, or move it to Stop sensor, or delete the
PCB memory information.
050208 ConrmationofP.C.B.existence
There is a possibility that there are 2 sheets of PCB on the input conveyor in Lane
A. Please remove PCB from Deceleration Sensor, or move it to Stop sensor, or
delete the PCB memory information.
050209 ConrmationofP.C.B.existence
There is a possibility that there are 2 sheets of PCB on the output conveyor in
Lane B. Please remove PCB from Deceleration Sensor, or move it to Stop sensor,
or delete the PCB memory information.
05020a ConrmationofP.C.B.existence
There is a possibility that there are 2 sheets of PCB on the shuttle conveyor in
input side. Please remove PCB from Deceleration Sensor, or move it to Stop
sensor, or delete the PCB memory information.
05020b ConrmationofP.C.B.existence
There is a possibility that there are 2 sheets of PCB on the shuttle conveyor in
output side. Please remove PCB from Deceleration Sensor, or move it to Stop
sensor, or delete the PCB memory information.
05020c ConrmationofP.C.B.existence
There is PCB on the input sensor of Lane A.
Please return PCB to the input conveyor and run it.
05020d ConrmationofP.C.B.existence
There is PCB on the input sensor of Lane B.
Please return PCB to the input conveyor and run it.
05020e ConrmationofP.C.B.existence
There is PCB on the input sensor.
Please return PCB to the input conveyor and run it.
05020f ConrmationofP.C.B.existence
There is no PCB in the machine. Please position a PCB.
050210 ConrmationofP.C.B.existence
Please put PCB on the positioning conveyor, and start it.
050211 ConrmationofP.C.B.existence
Please remove PCB from input position.
Cutout PCB cannot be transferred from input position.
050212 ConrmationofP.C.B.existence
Please remove the substrate at the upstream position.
The substrate for weight to exceed 2.5kg cannot be transported simultaneously.