2OM-1064-002.pdf - 第105页
3. Example of Pattern Program Creation (2) Example of Data Creation Placement Data (P) U01: Model A 9910-001 2-93 Tg0247-PM-PM Fig. 2.80 P- NO . X (mm) Y (mm) Z(T HE TA ) H (mm) FD R S V C C O M M E N T 0000 +0. 00 +0. 0…

Fig. 2.77-3
Fig. 2.77-4
3. Example of Pattern Program Creation
9910-001 2-92 Tg0247-PM-PM

3. Example of Pattern Program Creation
(2) Example of Data Creation
Placement Data (P) U01: Model A
9910-001 2-93 Tg0247-PM-PM
Fig. 2.80
P-NO. X(mm) Y(mm) Z(THETA) H(mm) FDR S V C COMMENT
0000 +0.00 +0.00 +0°00’ +0.00 000 - 00 -
0001 +0.00 +0.00 +0
°
00’ +0.00 000 - 00 9
0002 +20.00 +10.00 +180
°
00’ +0.00 301 - 00 -
0003 +10.00 +5.00 +0
°
00’ +0.00 601 - 00 -
0004 +0.00 +0.00 +0
°
00’ +0.00 000 - 00 0
0005 +45.00 +5.00 +270
°
00’ +0.00 401 - 00 -
0006 +35.00 +10.00 +90
°
00’ +0.00 501 - 00 -
0007 +0.00 +0.00 +0
°
00’ +0.00 000 - 00 5
0008 +55.00 +10.00 +0°00’ +0.00 301 - 00 -
0009 +65.00 +5.00 +180
°
00’ +0.00 601 - 00 -
0010 +0.00 +0.00 +0
°
00’ +0.00 000 - 00 P
Fig. 2.79
Placement Data (P) U03: Model C
P-NO. X(mm) Y(mm) Z(THETA) H(mm) FDR S V C COMMENT
0000 +0.00 +0.00 +0
°
00’ +0.00 000 - 00 -
0001 +10.00 +10.00 +0
°
00’ +0.00 301 - 00 -
0002 +30.00 +5.00 +180
°
00’ +0.00 601 - 00 -
0003 +0.00 +0.00 +0
°
00’ +0.00 000 - 00 7
0004 +10.00 +20.00 +90
°
00’ +0.00 401 - 00 -
0005 +0.00 +0.00 +0
°
00’ +0.00 000 - 00 1
0006 +30.00 +15.00 +270
°
00’ +0.00 501 - 00 -
0007 +0.00 +0.00 +0
°
00’ +0.00 000 - 00 Q
Fig. 2.78
Placement Data (P) U02: Model B
P-NO. X(mm) Y(mm) Z(THETA) H(mm) FDR S V C COMMENT
0000 +0.00 +0.00 +0
°
00’ +0.00 000 - 00 -
0001 +0.00 +0.00 +0
°
00’ +0.00 000 - 00 1
0002 +10.00 +5.00 +0
°
00’ +0.00 301 - 00 -
0003 +30.00 +9.00 +180
°
00’ +0.00 601 - 00 -
0004 +0.00 +0.00 +0
°
00’ +0.00 000 - 00 2
0005 +10.00 +20.00 +90
°
00’ +0.00 401 - 00 -
0006 +30.00 +24.00 +270
°
00’ +0.00 501 - 00 -
0007 +0.00 +0.00 +0
°
00’ +0.00 000 - 00 5
0008 +10.00 +5.00 +0
°
00’ +0.00 302 - 00 -
0009 +30.00 +9.00 +180
°
00’ +0.00 602 - 00 -
0010 +0.00 +0.00 +0
°
00’ +0.00 000 - 00 P

3. Example of Pattern Program Creation
Placement Data (O) U01
9910-001 2-94 Tg0247-PM-PM
Fig. 2.83
Notes: (a) Enter a numeral (0 to 9) as a delimiter (control command) in the
“C” data field for the priority sorting function.
• The machine does not place components for the steps where
block delimiters are set.
• One block starts from the step after a delimiter and ends at the
step before the next delimiter.
(b) The machine places components on a multi-unit P.C.B. (repeti-
tive patterns) in order of blocks “0, 1, 2, ... 9” (delimiters).
Fig. 2.82
Placement Data (O) U03
Fig. 2.81
Placement Data (O) U02
O-NO. X(mm) Y(mm) Z(THETA) H(mm) C COMMENT
0000 +0.00 +0.00 +0
°
00’ +0.00 -
0001 +5.00 +5.00 +0
°
00’ +0.00 -
0002 +45.00 +5.00 +0
°
00’ +0.00 -
0003 +5.00 +35.00 +0
°
00’ +0.00 -
0004 +45.00 +35.00 +0
°
00’ +0.00 -
0005 +0.00 +0.00 +0
°
00’ +0.00 E
O-NO. X(mm) Y(mm) Z(THETA) H(mm) C COMMENT
0000 +0.00 +0.00 +0
°
00’ +0.00 -
0001 +90.00 +5.00 +0
°
00’ +0.00 -
0002 +90.00 +30.00 +0
°
00’ +0.00 -
0003 +90.00 +55.00 +0
°
00’ +0.00 -
0004 +0.00 +0.00 +0
°
00’ +0.00 E
O-NO. X(mm) Y(mm) Z(THETA) H(mm) C COMMENT
0000 +0.00 +0.00 +0
°
00’ +0.00 -
0001 +5.00 +70.00 +0
°
00’ +0.00 -
0002 +0.00 +0.00 +0
°
00’ +0.00 E