2. Pattern Program 9910-001 2-67 Tg0247-PM-PM X1 (mm) and Y1 (mm) Set the coordinates of the first fiducial mark for the P .E.C. image recogni- tion function. F1 Set the mark data # of the first fiducial mark for the P .…

100%1 / 258
2.6.4 PLACEMENT DATA (V) Display [P.E.C. Data for Each Repeti-
tive Pattern]
When the [VISION DATA EDIT] key is pressed a the “PLACMENT DATA
(P) U01” display (Fig. 2.45-1 or Fig. 2.45-2), the following display appears on
the screen.
A list of P.E.C. data for each repetitive pattern is displayed.
Parameters can be edited at the display opened by pressing the [DATA EDIT]
key *13.
*2
*8
*9
*10
*12
*11
*16
*13
*3
*5
*4
*1
2. Pattern Program
9910-001 2-66 Tg0247-PM-PM
Fig. 2.48
Description of Parameters
V-NO
This shows the step Nos. of the placement data (V).
(Only V-0000 is used.)
V
[Setting of Repetitive Patterns]
When multi-unit P.C.B.’s (repetitive patterns) are used and the P.E.C. func-
tion is implemented, set “02” in the text field labeled “V” of the V-0000
step.
00: B.B.R. P.E.C. Recognition Function “OFF”
01: B.B.R. P.E.C. Recognition Function “ON” (1-Point Recognition)
02: B.B.R. P.E.C. Recognition Function “ON” (2-Point Recognition)
Ref.: As both V data shown at the placement data (V) and (P) displays
are the same, the V data can be entered at either display.
[Setting of Each Individual Placement Points]
Set each individual placement points in the text field labeled “V” of the
placement step.
00: P.E.C. Recognition “OFF”
01: P.E.C. Recognition “ON” (1-Point Recognition)
02: P.E.C. Recognition “ON” (2-Point Recognition)
Note: Set “ON” in the “P.E.C. RECOGNITION” data box and in the “LO-
CAL” data box of the label “P.E.C. RECOGNITION MODE” at the
“OPERATION DATA” display.
2. Pattern Program
9910-001 2-67 Tg0247-PM-PM
X1 (mm) and Y1 (mm)
Set the coordinates of the first fiducial mark for the P.E.C. image recogni-
tion function.
F1
Set the mark data # of the first fiducial mark for the P.E.C. image recogni-
tion function.
The mark data # registered at the “P.E.C. MARK DATA EDIT” display
(Operation Data) can be selected and set as F1 parameters.
X2 (mm) and Y2 (mm)
Set the coordinates of the second fiducial mark for the P.E.C. image recog-
nition function.
F2
Set the mark data # of the second fiducial mark for the P.E.C. image recog-
nition function.
The mark data # registered at the “P.E.C. MARK DATA EDIT” display
(Operation Data) can be selected and set as F2 parameters.
C
Set a control command.
Ref.: The same control commands as used in placement data (P) can be
set.
3. Example of Pattern Program Creation
9910-001 2-68 Tg0247-PM-PM
3. Example of Pattern Program Creation
3.1 Example 1
Described in this session is how to create a pattern program for component
placement exemplified in Fig. 2.49.
Fig. 2.49