2OM-1064-002.pdf - 第159页

OUTPUT CONVEYOR TIMER #2 The operating time of the output conveyor can be limited by this timer when a P .C.B. is transferred inside the machine by the output conveyor . This timer measures the operating time of the outp…

100%1 / 258
Fig. 3.5-4
P.C.B. TRANSFER-DIR.
Set “L R” or “R L” in the data box to specify the P.C.B.
transfer direction.
[L R]
P.C.B.’s are transferred from left to right.
[R L]
P.C.B.’s are transferred from right to left.
Note: Whenever the set parameter is changed, the zeroing
operation must be performed.
INPUT CONVEYOR TIMER #1
The operating time (P.C.B. reception from the input machine)
of the input conveyor can be limited by this timer.
This timer measures the operating time of the input conveyor
and is used to detect an interrupted P.C.B.
Add 2 seconds (approx.) to the time required for P.C.B. re-
ception from the input machine and set.
Data Input Range: 0 to 99 seconds
INPUT CONVEYOR TIMER #2
The operating time of the input conveyor can be limited by
this timer when a P.C.B. is transferred inside the machine by
the input conveyor.
This timer measures the operating time of the input conveyor
and is used to detect an interrupted P.C.B.
Note: This time is also used for the timer of EL/ER conveyor
(option).
Data Input Range: 0 to 99 seconds
OUTPUT CONVEYOR TIMER #1
The operating time of the output conveyor can be limited by
this timer when a P.C.B. is received by the output machine.
Add 2 seconds (approx.) to the time required for P.C.B. trans-
fer to the output machine and set.
Data Input Range: 0 to 99 seconds
2. P.C.B. TRANSFER MODE SET-UP Display
TIM-5100RR
P.C.B. Transfer Reference: Rear Side of Machine
P.C.B. Transfer : R L
P.C.B. Positioning Reference: R-BACK
A
L Conveyor
(Output Conveyor)
R Conveyor
(Input Conveyor)
L Conveyor
P.C.B. Stopper
R Conveyor
P.C.B. Stopper
P Conveyor
(P.C.B. Positioning Section)
P.C.B. Transfer
Reference
P.C.B.
P.C.B. Flow Direction
Movable
Side
Placement Reference
0103-003 3-10 Tg0247-PM-PM
OUTPUT CONVEYOR TIMER #2
The operating time of the output conveyor can be limited by
this timer when a P.C.B. is transferred inside the machine by
the output conveyor.
This timer measures the operating time of the output conveyor
and is used to detect an interrupted P.C.B.
Note: This time is also used for the timer of EL/ER conveyor
(option).
Data Input Range:
0 to 99 seconds
Note: When “STANDARD” is set in the “OUTPUT MODE”
data box, the machine stops in an error condition after
this timer has reached the set time.
OUTPUT INTERVAL TIMER
When “INTERVAL” (P.C.B. output without handshaking) is
set in the “OUTPUT MODE” data box, this timer is used to
set an output interval time.
Data Input Range: 0 to 99 seconds
2. P.C.B. TRANSFER MODE SET-UP Display
0103-003 3-11 Tg0247-PM-PM
Fig. 3.6
Y-CLAMP TIMER
Set a period of time during which the Y pusher moves forward
or backward for P.C.B. alignment in Y direction (horizontal
P.C.B. positioning). The set parameter is used commonly for
both forward and backward movements.
The Y pusher is not provided with any sensors for detection of
the forward or backward movement because the Y pusher
moves only a short distance. Therefore, the timing of move-
ment is controlled by the software-based timer.
Default: 0.3 seconds
Enter a period of time during which the Y alignment is
made completely.
Whenever the speed of the forward or the backward move-
ment is adjusted, it is required to change the set parameter
to avoid any impact which may be given to a P.C.B. dur-
ing Y alignment.
Data Input Range: 0 to 99 seconds
Note: When the parameter is too large, excessively long
time will be required for P.C.B. positioning or re-
leasing.
Output Conveyor ON
Transfer of Subsequent P.C.B.
Controlled by the
output conveyor
timer #1
Output Interval Timer
This timer gives an interval
time until the subsequent
P.C.B. is transferred.
Fig. 3.7
LINE LETTER
Set a line letter (interface address to the programming device
(option)) in the component placement system.
Data Input Range: A to Z (Internal Data: ASCII)
DEVICE NUMBER
Set a device number in the component placement system line.
This data is used to identify the object machine when several
machines (same models) are assembled, forming one system
line.
(Interface Address to Programming Device)
Data Input Range: 01 to 26 (Internal Data: ASCII “A to Z”)
3. MACHINE COMM. ADDRESS SET-UP Display
9910-001 3-12 Tg0247-PM-PM
3. MACHINE COMM. ADDRESS SET-UP Display
When data is exchanged between a machine and an external device such as a
programming device (option), it is required to specify the machine (line letter
and device No.).
*1 When a component placement system line is constructed, it is advisable
that a common line letter be used in one system (combination of input,
main, and output machines).
*2 “Device Number” is an address data used to identify the object machine
when there is another machine of the same type in the same line.
Notes: (a) When data is exchanged between the main machine and the pro-
gramming device (option), the same line letter must be entered on
the programming device side.
(b) Even if a machine address data is changed, machine operation
remains unchanged. However, if an address data is changed after
each offset data for the machine is stored in the programming
device, the offset data may not be reloaded to the machine.
When the [MACHINE COMM. ADDRESS SET-UP] key is pressed at the
“DEVICE DATA” display, the following display appears on the screen.