Order of Placement (2.1) P-0001 and P-0002 of U02: O-0001 → P-0002 and P-0001 of U02: O- 0002 → P-0001 and P-0002 of U02: O-0003 (2.2) P-0005 and P-0006 (Block “0”) of U03 (2.3) P-0002 and P-0003 of U01: O-0001 → P-0003 …

100%1 / 258
3. Example of Pattern Program Creation
Placement Data (O) U01
9910-001 2-94 Tg0247-PM-PM
Fig. 2.83
Notes: (a) Enter a numeral (0 to 9) as a delimiter (control command) in the
“C” data field for the priority sorting function.
The machine does not place components for the steps where
block delimiters are set.
One block starts from the step after a delimiter and ends at the
step before the next delimiter.
(b) The machine places components on a multi-unit P.C.B. (repeti-
tive patterns) in order of blocks “0, 1, 2, ... 9” (delimiters).
Fig. 2.82
Placement Data (O) U03
Fig. 2.81
Placement Data (O) U02
O-NO. X(mm) Y(mm) Z(THETA) H(mm) C COMMENT
0000 +0.00 +0.00 +0
°
00’ +0.00 -
0001 +5.00 +5.00 +0
°
00’ +0.00 -
0002 +45.00 +5.00 +0
°
00’ +0.00 -
0003 +5.00 +35.00 +0
°
00’ +0.00 -
0004 +45.00 +35.00 +0
°
00’ +0.00 -
0005 +0.00 +0.00 +0
°
00’ +0.00 E
O-NO. X(mm) Y(mm) Z(THETA) H(mm) C COMMENT
0000 +0.00 +0.00 +0
°
00’ +0.00 -
0001 +90.00 +5.00 +0
°
00’ +0.00 -
0002 +90.00 +30.00 +0
°
00’ +0.00 -
0003 +90.00 +55.00 +0
°
00’ +0.00 -
0004 +0.00 +0.00 +0
°
00’ +0.00 E
O-NO. X(mm) Y(mm) Z(THETA) H(mm) C COMMENT
0000 +0.00 +0.00 +0
°
00’ +0.00 -
0001 +5.00 +70.00 +0
°
00’ +0.00 -
0002 +0.00 +0.00 +0
°
00’ +0.00 E
Order of Placement
(2.1) P-0001 and P-0002 of U02: O-0001 P-0002 and P-0001 of U02: O-
0002 P-0001 and P-0002 of U02: O-0003
(2.2) P-0005 and P-0006 (Block “0”) of U03
(2.3) P-0002 and P-0003 of U01: O-0001 P-0003 and P-0002 of U01: O-
0002 P-0002 and P-0003 of U01: O-0003 P-0003 and P-0002
(Block “1”) of U01: O-0004
(2.4) P-0006 of U02: O-0001 P-0006 of U02: O-0002 P-0006 (Block
“1”) of U02: O-0003
(2.5) P-0005 and P-0006 of U01: O-0001 P-0006 and P-0005 of U01: O-
0002 P-0005 and P-0006 of U01: O-0003 P-0006 and P-0005
(Block “2”) of U01: O-0004
(2.6) P-0008 and P-0009 of U01: O-0001 P-0009 and P-0008 of U01: O-
0002 P-0008 and P-0009 of U01: O-0003 P-0009 and P-0008
(Block “5”) of U01: O-0004
(2.7) P-0008 and P-0009 (Block “5”) of U03
(2.8) P-0004 of U02: O-0001 P-0004 of U02: O-0002 P-0004 (Block
“7”) of U02: O-0003
(2.9) P-0002 and P-0003 (Block “9”) of U03
3. Example of Pattern Program Creation
9910-001 2-95 Tg0247-PM-PM
3. Example of Pattern Program Creation
3.2.8 Data for Polar Coordinate Conversion Function
When unit P.C.B.’s are arranged at arbitrary angles on a multi-unit P.C.B., this
function converts polar coordinates after parameters (arrangement angle of
each pattern) are entered in the “Z (THETA)” data field of the placement data
(O).
(1) Pattern Sample
9910-001 2-96 Tg0247-PM-PM
Fig. 2.84-2
Fig. 2.84-1