2OM-1064-002.pdf - 第193页
Fig. 5.25 BEAM A/BEAM B HEAD #1/HEAD #2, X (horizontal), Y (ver- tical) This offset data is used to correct the positional deviation (placement coordinates) caused due to the deviation of straightness (skew) of each indi…

Fig. 5.24
BEAM A/BEAM B HEAD #1/HEAD #2 X (Horizontal), Y (Ver-
tical)
This offset data is used to correct the positional deviation
(placement coordinates) caused due to the deviation of
straightness (skew) of each individual head up/down axis
guides. The set parameters are added to the amount of beam
movement (travel) for component placement.
Note: The offset values are not reflected on the automatic
teaching operation.
4. HEAD MASTER OFFSET Display
When the [HEAD MASTER OFFSET] key is pressed at the “OFFSET DATA”
display, the following display appears on the screen.
9910-001 5-22 Tg0247-PM-PM
4. HEAD MASTER OFFSET Display

Fig. 5.25
BEAM A/BEAM B HEAD #1/HEAD #2, X (horizontal), Y (ver-
tical)
This offset data is used to correct the positional deviation
(placement coordinates) caused due to the deviation of
straightness (skew) of each individual head up/down axis
guides. The set parameters are added to the amount of beam
movement (travel) for component placement.
This offset data is automatically calculated through teaching
operation which is performed, using the jig component sta-
tioned at the teaching plate section inside the machine.
5. HEAD OFFSET Display
When the [HEAD OFFSET] key is pressed at the “OFFSET DATA” display,
the following display appears on the screen.
5. HEAD OFFSET Display
9910-001 5-23 Tg0247-PM-PM

Fig. 5.26
BEAM A HEAD #1, X (horizontal), Y (vertical)
This offset data is used to set the distance between the scan-
ning coordinate center (actual position) of the P.E.C. camera
on Beam A and the rotational center of Head #1. The distances
deviating from the design values must be entered in each data
box. The parameters must be those viewed in the X/Y coordi-
nate system (PL-XY) for P.C.B. positioning.
• Design Values (distances between the center of P.E.C. cam-
era on Beam A and the rotational center of Head #1)
X : +54.000 mm
Y : +0.000 mm
When the rotational center of Head #1 is actually located at
the position shown in the figure below, the offset parameters
representing the X (horizontal) and Y (vertical) must be pro-
vided with plus (+) signs.
0004-002 5-24 Tg0247-PM-PM
6. HEAD CENTER OFFSET Display
6. HEAD CENTER OFFSET Display
When the [HEAD CENTER OFFSET] key is pressed at the “OFFSET DATA”
display, the following display appears on the screen.
Center of P.E.C. Camera on Beam A
Rotational Center (Design Position)
of Head #1 on Beam A
Actual Rotational Center of Head #2 on Beam A
Rotational Center (Design Position)
of Head #2 on Beam A
(Front Side of Machine)
Top View
Fig. 5.27
This offset data is automatically calculated through teaching
operation which is performed, using the jig component sta-
tioned at the teaching plate inside the machine.