2.5.2 Vibratory Stick Feeders When the [DA T A EDIT] key is pressed at the display (Fig. 2.32) for “V ibra- tory Stick Feeder A”, the following display appears on the screen. Every time the [SCREENS] key is pressed, anot…

100%1 / 258
*8 [COMPONENT ID INITIALIZED] key
When this key is pressed, the key turns red, indicating that the initializa-
tion mode is set.
When the [SET] key is pressed in the initialization mode, the component
ID is deleted and left blank.
Once the initialization operation is performed, the initialization mode is
automatically canceled.
Ref.: Difference between the [COMPONENT ID INITIALIZED] and
[STEP DELETE] Keys
The [STEP DELETE] key is used to delete a feeder No. (FDR NO).
The [COMPONENT ID INITIALIZED] key is used to clear a com-
ponent ID.
*9 [VIB. STICK UNIT] Key
When this key is pressed, a vibratory stick feeder unit is registered for the
feeder No. at the line cursor position.
One vibratory stick feeder unit occupies six feeder slot Nos. (lanes).
The following table shows the feeder slot Nos. (lanes) for which vibratory
stick feeder units can be registered.
The parameters for the vibratory stick feeder units can be entered at the
displays described in “2.5.2 Vibratory Stick Feeders of Section 2”.
*10 [PROGRAM CHECK] Key
0004-002 2-41 Tg0247-PM-PM
2. Pattern Program
Feeder Base
Nos.
Unit Nos.
Occupied Lanes
(FDR NO)
Vibratory Stick Feeder Unit 1 101 to 106
Feeder Base #1 Vibratory Stick Feeder Unit 2 107 to 112
Vibratory Stick Feeder Unit 3 113 to 118
Vibratory Stick Feeder Unit 4 121 to 126
Feeder Base #2 Vibratory Stick Feeder Unit 5 127 to 132
Vibratory Stick Feeder Unit 6 133 to 138
Vibratory Stick Feeder Unit 7 201 to 206
Feeder Base #3 Vibratory Stick Feeder Unit 8 207 to 212
Vibratory Stick Feeder Unit 9 213 to 218
Vibratory Stick Feeder Unit 10 221 to 226
Feeder Base #4 Vibratory Stick Feeder Unit 11 227 to 232
Vibratory Stick Feeder Unit 12 233 to 238
When this key is pressed, the edited pattern program is checked.
*11 CARRIER DATA, DIR, TYPE, WD
Shown in each data field are the parameters set in the component library
data.
*12 NOZZLE ID, SHORT, LONG
Shown in each data field are the parameters set in the component library
data.
2.5.2 Vibratory Stick Feeders
When the [DATA EDIT] key is pressed at the display (Fig. 2.32) for “Vibra-
tory Stick Feeder A”, the following display appears on the screen.
Every time the [SCREENS] key is pressed, another display appears on the
screen.
*1
*2
Fig. 2.35-1
[SCREENS] Key
Fig. 2.35-2
Fig. 2.35-3
0004-002 2-42 Tg0247-PM-PM
2. Pattern Program
0004-002 2-43 Tg0247-PM-PM
2. Pattern Program
*1 ALTERNATE FDR.
[MODE] Key : “ON” or “OFF” can be set to determine whether or not
the alternate feeder function should be used.
Ref.: It is recommended to set it to "OFF".
[FDR.] Key : When a component pick-up error occurs continuously
(Component Library: ERROR PROCESS DATA 1 and
2), the destination feeder No. for alternate use can be speci-
fied.
*2 OFFSET
[X (mm)] : Enter the distance in the X direction between the reference
position of the vibratory stick feeder unit and the pick-up po-
sition.
[Y (mm)] : Enter the distance between the end (pushing face) of the vibra-
tory stick feeder and the pick-up position.
Vacuum Nozzle
Carrier Stick Magazine
Carrier Stick Magazine
Component
Pick-Up Level
(Component Library)
X
+
++
+
+
++
+
Y
Pick-Up Points
Position Offset Y
Position Offset X
Reference Point of Pick-Up Level
Reference Point of Vibratory Stick Feeder Unit
Vibratory Stick
Feeder Unit
Vibratory Stick
Feeder Unit
X Direction Offset
Reading Gauge
Fig. 2.36