2OM-1064-002.pdf - 第156页

[PLACE REF .] (Placement Coordinates Reference: ) The placement coordinates reference is given priority for positioning. Scope of Positioning (1) The P .C.B.’ s at Standby Position A in the figures be- low are sent ahead…

100%1 / 258
P.C.B. LOCATE MODE
Set the sequence in which a P.C.B. should be transferred and
positioned.
Select “PRI PCB STR” or “PLACE REF.”.
“PRI PCB STR” : Select this when the placement coordinates
reference for the P.C.B. must be specified
on the opposite side of the P.C.B. stopper
location for P.C.B. positioning.
“PLACE REF.” : Select this when the placement coordinates
reference must be specified on the side
where the P.C.B. is pushed against the
P.C.B. stopper.
Refer to “6.5 P.C.B. Transfer of Section 1 in Volume 1” for
details.
Notes: (a) The direction of the P.C.B. stopper block is ad-
justed in compliance with the setting upon ship-
ment of the machine.
When the setting is changed, it is required to
change the direction of the P.C.B. stopper block
according to the changed setting.
Refer to “Section 2 Adjustment of P.C.B. Posi-
tioning Section in Volume 5” for details.
(b) Push the P.C.B. against the P.C.B. stopper for
positioning.
When an area of the P.C.B. has a cutout, etc.,
and is pushed against the P.C.B. stopper, the
P.C.B. cannot be positioned correctly.
(c) When a P.C.B. is positioned by the pilot pin (op-
tion), set “PLACE REF.” in the data box.
[PRI PCB STR] (Placement Coordinates Reference: )
P.C.B.’s are positioned based on the stopper located ahead
in the P.C.B. flow direction.
Scope of Positioning
(1) The P.C.B.’s at standby position A in the figures be-
low are sent to the P.C.B. stoppers.
(2) The P.C.B. backup base ascends and works to position
the P.C.B. vertically and horizontally (alignment in Y
direction).
2. P.C.B. TRANSFER MODE SET-UP Display
9910-001 3-7 Tg0247-PM-PM
L Conveyor
(Input Conveyor)
R conveyor
(Output Conveyor)
L Conveyor
P.C.B. Stopper
R Conveyor
P.C.B. Stopper
P Conveyor
(P.C.B. Positioning Section)
Movable Side
P.C.B. Transfer Reference
P.C.B.
Note b
P.C.B. Flow Direction
TIM-5100FL
A
Fig. 3.4-1
[PLACE REF.] (Placement Coordinates Reference: )
The placement coordinates reference is given priority for
positioning.
Scope of Positioning
(1) The P.C.B.’s at Standby Position A in the figures be-
low are sent ahead of the P.C.B. stoppers for position-
ing.
(2) An action takes place to bring the P.C.B. back to the
P.C.B. stopper for positioning.
(3) The P.C.B. backup base ascends and works to position
the P.C.B. vertically and horizontally (alignment in Y
direction).
Note: Because an action takes place to return the P.C.B.
at P.C.B. positioning, the P.C.B. transfer time be-
comes longer, compared with the time required
when “PRI PCB STR” is set in the data box.
TIM-5100RR
A
L Conveyor
(Output Conveyor)
R Conveyor
(Input Conveyor)
L Conveyor
P.C.B. Stopper
R Conveyor
P.C.B. Stopper
P Conveyor
(P.C.B. Positioning Section)
P.C.B. Transfer
Reference
P.C.B.
P.C.B. Flow Direction
Movable
Side
TIM-5100FR
L Conveyor
(Output Conveyor)
R Conveyor
(Input Conveyor)
L Conveyor
P.C.B. Stopper
R Conveyor
P.C.B. Stopper
P Conveyor
(P.C.B. Positioning Section)
P.C.B. Transfer Reference
A
P.C.B.
P.C.B. Flow Direction
Movable
Side
L Conveyor
P.C.B. Stopper
TIM-5100RL
L Conveyor
(Input Conveyor)
R conveyor
(Output Conveyor)
R Conveyor
P.C.B. Stopper
P Conveyor
(P.C.B. Positioning Section)
P.C.B. Transfer Reference
P.C.B.
Movable
Side
P.C.B. Flow Direction
A
Fig. 3.4-2
2. P.C.B. TRANSFER MODE SET-UP Display
Fig. 3.4-3
Fig. 3.4-4
9910-001 3-8 Tg0247-PM-PM
TIM-5100FL
P.C.B. Transfer Reference: Front Side of Machine
P.C.B. Transfer : L R
P.C.B. Positioning Reference: L-FRONT
2. P.C.B. TRANSFER MODE SET-UP Display
A
L Conveyor
(Output Conveyor)
R Conveyor
(Input Conveyor)
L Conveyor
P.C.B. Stopper
R Conveyor
P.C.B. Stopper
P Conveyor
(P.C.B. Positioning Section)
P.C.B. Transfer
Reference
P.C.B.
P.C.B. Flow Direction
Movable
Side
Placement Reference
Placement Reference
R Conveyor
(Output Conveyor)
L Conveyor
(Input Conveyor)
L Conveyor
P.C.B. Stopper
R Conveyor
P.C.B. Stopper
P Conveyor
(P.C.B. Positioning Section)
P.C.B.
P.C.B. Flow Direction
Movable
Side
P.C.B. Transfer
Reference
A
Placement Reference
R Conveyor
(Output Conveyor)
L Conveyor
(Input Conveyor)
L Conveyor
P.C.B. Stopper
R Conveyor
P.C.B. Stopper
P Conveyor
(P.C.B. Positioning Section)
P.C.B. Transfer Reference
P.C.B.
P.C.B. Flow Direction
Movable
Side
A
Fig. 3.5-1
TIM-5100RL
P.C.B. Transfer Reference: Rear Side of Machine
P.C.B. Transfer : L R
P.C.B. Positioning Reference: L-BACK
Fig. 3.5-2
TIM-5100FR
P.C.B. Transfer Reference: Front Side of Machine
P.C.B. Transfer : R L
P.C.B. Positioning Reference: R-FRONT
Fig. 3.5-3
9910-001 3-9 Tg0247-PM-PM